Flexible AC Current Probe
- Specification
- Application
CE CAT III 600V
Electrical Specifications:
(23℃±3℃, 50/60Hz, conductor located at the center of the flexible loop)
Sliding Switch Position |
600A AC |
6000A AC |
||
Range |
6 – 600A |
60 – 6000A |
||
Output Select |
600mV |
1V |
600mV |
1V |
Output Signal |
1mV/A |
1.66mV/A |
0.1mV/A |
0.166mV/A |
Accuracy |
1% of full scale |
1% of full scale |
||
Linearity (10 to 100%) |
0.2% of reading |
0.2% of reading |
||
Position Sensitivity |
2% of full scale |
2% of full scale |
||
External Field (200 mm from the head, < 40A/m) |
1% of full scale |
1% of full scale |
||
Phase Error |
< ± 1˚ |
< ±1˚ |
||
Temperature Coefficient |
0.02% of reading / ˚C |
0.02% of reading / ˚C |
Sliding Switch Position |
60A AC |
|
Range |
6 – 60A |
|
Output Select |
600mV |
1V |
Output Signal |
10mV/A |
16.6mV/A |
Accuracy |
3% of full scale |
|
Linearity (10 to 100%) |
0.2% of reading |
|
Position Sensitivity |
3% of full scale |
|
External Field (200 mm from the head, < 40A/m) |
1% of full scale |
|
Phase Error |
< ± 2˚ |
|
Temperature Coefficient |
0.02% of reading / ˚C |
DC offset: < 20mVDC (600A AC range)
< 100mVDC (60A AC range)
< 20mVDC (6000A AC range)
Noise: < 2mVACRMS
Bandwidth (-3dB): 10 to 10 KHz
Load Impedance: 1KΩ
Battery: 2 x AA 1.5V Alkaline (2000mAHrs)
Battery Life: 300 Hours
General Specifications:
Probe Length: 3000-36 |
36 in / 920 mm |
Minimum Bending Diameter: |
35mm |
Connector Diameter: |
23mm |
Cable Diameter: |
14mm |
Cable Length from Probe to Box: |
1700mm |
Cable Length from Box to Output: |
1700mm |
Dimension (Box): |
130mm(L) x 80mm(W)x 43mm(H) 5.1”(L) x 3.1”(W) x 1.7”(H) |
Battery Type: |
two 1.5V SUM-3 (Alkaline, 2000mAHrs) |
Battery Life: |
300 Hours |
Operating Temperature: |
-10˚C to 85˚C |
Operating Humidity: |
15% to 85% RH |
Altitude: |
up to 2000M |
Storage Temperature: |
-20˚C to 85˚C |
Storage Humidity: |
15% to 85% RH |
Weight: |
450g (battery included) |
Accessories: |
Carrying case x 1 Users manual x 1 Batteries 1.5V x 2 |