AC Clamp Meter
- Specification
- Application
DC Voltage(Autorange & Manual)
Range |
Resolution |
Accuracy |
Input Impedance |
Overload protection |
400mV |
0.1 mV |
±(0.75%rdg+2dgts) |
≧1000MΩ |
660Vrms |
4V |
0.001V |
≒ 11MΩ |
||
40V |
0.01V |
≒ 10MΩ |
||
400V |
0.1V |
|||
600V |
1V |
AC Voltage(Autorange & Manual)
Range |
Resolution |
Accuracy |
Input impedance |
Overload protection |
Frequency Response |
4V |
0.001V |
±(1.2%rdg +5dgts) |
≒ 11MΩ |
660Vrms |
40~450Hz |
40V |
0.01V |
≒ 10MΩ |
|||
400V |
0.1V |
||||
600V |
1V |
±( 1.5%rdg |
AC Current(Autoange & Manual)
Range |
Resolution |
Accuracy |
Overload protection |
Frequency Response |
400A |
0.1A |
±( 2%rdg + 10 dgts ) |
1100A |
40~450 Hz |
1000A |
1 A |
Frequency ( Hz )(Autorange only for current)
Range |
Resolution |
Accuracy |
Sensitivity |
Overload protection |
100 Hz |
0.01 Hz |
±( 0.5%rdg+5dgts) |
5A |
1100A |
1KHz |
0.1 Hz |
Frequency ( Hz )(Autorange only for voltage)
Range |
Resolution |
Accuracy |
Sensitivity |
Overload protection |
100 Hz |
0.01 Hz |
±( 0.1%rdg+2dgts) |
100mV |
660Vrms |
1KHz |
0.1 Hz |
|||
10KHz |
0.001KHz |
|||
100KHz |
0.01 KHz |
|||
800KHz |
0.1 KHz |
1V |
Resistance ( Ω )(Autorange & Manual)
Range |
Resolution |
Accuracy |
Open circuit Voltage |
Overload protection |
400Ω |
0.1Ω |
±( 1%rdg+5dgts) |
≦0.5 VDC |
660Vrms |
4KΩ |
0.001KΩ |
±( 1%rdg+3dgts) |
||
40KΩ |
0.01 KΩ |
|||
400KΩ |
0.1 KΩ |
|||
4MΩ |
0.001MΩ |
|||
40MΩ |
0.01 MΩ |
±( 1.5%rdg+3dgts) |
Audible Continuity
Range |
Continuity beeper |
Open Circuit Voltage |
Overload protection |
|
≦40Ω |
≦0.5V |
660Vrms |
Diode test
Range |
Resolution |
Accuracy |
Overload protection |
|
0.001V |
±( 1%rdg+2dgts ) |
660Vrms |
SPECIFICATIONS
Numerical Display :3 3/4 digit liquid crystal display (LCD) maximum reading 3999.
Range Selection :All ranges are selected by a single range switch.
Over Range Indication:LCD will show a "4" flashing in the highest position accompanied with a
continuous beeping. (except for ranges of 1000A AC , and 600VDC 600VAC ).
LowBattery Indication:The is displayed when the battery voltage drops below the operating voltage.
Sampling Rate : 20 times/sec ( Barograph ) 2 times/sec (Digital Display)
Power Source :one 006p 9V or IEC 6F22or NEDA 1604 Battery.
Battery Life :300hr approx. (Alkaline)
Polarity :Automatic polarity "–" display for negative input.
Auto power off time :Approx. 30 minutes.
Operating Temperature:0℃ to 50℃
and Humidity (32℉ to 122℉) below 80%RH
StorageTemperature :-10℃ to 60℃ and Humidity (14℉ to 140℉) below 70%RH
Dimensions :239(L)x66(W)x34(H)mm
Weight :Approx. 430g