PROVA 6830A-5

Power and Harmonics Analyzer - Model 3006 (6000A)

Availability: In stock
  • Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W.
  • True RMS value (V123 and I123).
  • Active Power (W, KW, MW, GW).
  • Apparent and Reactive Power (KVA, KVAR).
  • Power Factor (PF), Phase Angle (Φ).
  • Energy (WH, KWH, KVARH, PFH).
  • AC Current (see below) and Voltage measurement: True RMS, Auto Range.
     1. 6830A+6801: 0.04A to 100A
     2. 6830A+6802: 0.4A to 1000A
     3. 6830A+3007: 10A to 3000A
     4. 6830A+3009: 6A to 1200A
     5. 6830A+3006: 20A to 6000A
  • Capable of analyzing IT standby power consumption to the maximum demand of a factory.
  • Display of 35 Parameters in One Screen (3P4W).
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios.
  • Display of Overlapped Voltage and Current Waveform.
  • Average Demand (AD in W, KW, MW).
  • Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period.
  • Harmonic Analysis to the 99th Order.
  • Display of 50 Harmonics in one Screen with Waveform.
  • Display of Waveform with Peak Values (1024 Samples / Period).
  • Analysis of Total Harmonic Distortion (THD-F).
  • Graphic Phasor Diagram with 3 Phase System Parameters.
  • Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%).
  • DIP, SWELL, and OUTAGE are included in transient events.
  • 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR).
  • 3 Phase Voltage or Current Unbalance Factor (d0%, d2%).
  • Calculated Unbalanced Current through Neutral Line (In).
  • 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system).
  • Output of Waveform, Power Parameters and Harmonics at Command.
  • Large Dot Matrix LCD Display with Backlight.
  • Software to work with PC via Optical Isolated RS-232C to USB Interface.
  • Built-in timer and calendar for data logging.
     
     Conductor Size:
     ■ Model 6801(100A) 30mm(approx)
      210mm(L)*62mm(W)*36mm(H),200g(Weight)
     ■ Model 6802(1000A) 55mm(approx),64*24mm(bus bar)
      244mm(L)*97mm(W)*46mm(H),600g(Weight)
     ■ Model 3007 (3000A) 24in/610mm(Probe Length)
      130mm(L)*80mm(W)*43mm(H),410g(Weight)
     ■ Model 3009 (1200A) 18in/460mm(Probe Length)
      130mm(L)*80mm(W)*43mm(H),390g(Weight)
     ■ Model 3006(6000A)
      130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
    • Shipping
    • Payments
    • Quantity
    • US$ 2475Log in for sale price
    To show price, please join membership and log in.
    Power and Harmonics Analyzer - Model 3006 (6000A)
    Power and Harmonics Analyzer - Model 3006 (6000A)
    • Specification
    • Application

     

    Electrical Specifications: (23±5) 

    AC Watt 

    Range(0 to 6000A)
    Resolution
    Accuracy of Readings
    > 20 V and > 60A
    < 20V or < 60A
    10.0 – 999.9 W
    0.2W
      ±1% of range
      ±2% of range
    1.000 – 9.999 KW
    0.002 KW
    10.00 – 99.99 KW
    0.02 KW
    100.0 – 999.9 KW
    0.2 KW
    1000 – 9999 KW
    2 KW

    Range of VT (Voltage Transformer) Ratio: 1 to 3000 

    AC Apparent Power (VA, from 0.000 VA to 9999 KVA):  VA = V r.m.s. x A r.m.s 

    AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR):  VAR = (VA2 –  W2) 

    AC Active Energy (mWH, WH, or KWH, from 0mWH to 999,999KWH): WH = W * Time (in hours) 

     

    AC Current  (Auto range, TRMS, Overload Protection AC 6000A) 

    Range
    Resolution
    Accuracy of Readings
    20.0 – 600.0A
    0.2A
    ±1% of range
    600.0 – 6000A
    0.2A / 2A

     

    AC Voltage  (Auto range, TRMS, Overload Protection AC 800V) 

    Range
    Resolution
    Accuracy of Readings
    20.0 V – 500.0 V (Phase to Neutral)
    0.1 V
    ±0.5% ± 5dgts
    20.0 V – 600.0 V (Phase to Phase)

     Range of VT (Voltage Transformer) Ratio: 1 to 3000 

     

    Harmonics of AC Voltage in Percentage 

    Range
    Resolution
    Accuracy
    1 – 20th
     0.1%
    ±2%
    21 – 49th
    ±4% of reading ± 2.0%
    50 – 99th
    ±6% of reading ± 2.0%

     

     Harmonics of AC Voltage in Magnitude 

    Range
    Resolution
    Accuracy
    1 – 20th
     
    0.1V
    ±2% ± 0.5V
    21 – 49th
    ±4% of reading ± 0.5V
    50 – 99th
    ±6% of reading ± 0.5V

     

    Peak Value of ACV (peak value > 20V) or ACA (peak value > 60A), VT=1 

    Range
    Sampling Time
    Accuracy of Reading
    50 Hz
    19μs
    ± 5% ± 30 digits
    60 Hz
    16μs

     

    Crest Factor (C.F.) of ACV (peak value >20V) or ACA (RMS value > 60A), VT=1 

    Range
    Resolution
    Accuracy of Readings
    1.00 – 99.99
    0.01
    ± 5% ± 60 digits

     

    Harmonics of AC Current in Percentage 

    Range
    Resolution
    Accuracy
    1 – 20th
     
    0.1%
    ±2%
    21 – 50th
    ±6%
    51 – 99th
    ±10%

     

    Harmonics of AC Current in Magnitude 

    (1 to 99th order, min. current at the 50 or 60 Hz, True RMS < 600A) 

    Range (0 – 600A)
    Resolution
    Accuracy
    1 – 20th
     
    0.1%
    ±2% of reading ± 8A
    21 – 50th
    ±4% of reading ± 8A
    51 – 99th
    ±6% of reading ± 8A

     (1 to 99th order, min. current at the 50 or 60 Hz, 6000A > True RMS > 600A) 

    Range (600–6000A)
    Resolution
    Accuracy
    1 – 20th
     
    0.1%
    ±2% of reading ± 80A
    21 – 50th
    ±4% of reading ± 80A
    51 – 99th
    ±6% of reading ± 80A

     

    Power Factor  (PF) 

    Range
    Resolution
    Accuracy
    > 20V and > 60A
    < 20V or < 60A
    0.000 – 1.000
    0.001
    ± 0.04
    ±0.1

     

    Phase Angle  (Φ, V > 20V, A > 60A) 

    Range
    Resolution
    Accuracy
    -180° to 180°
    0.1°
    ± 2°
    0° to 360°

     

    Frequency of ACV (RMS value > 10V) or ACA (RMS value > 60A) 

    Range
    Resolution
    Accuracy
    45 – 65 Hz
    0.1 Hz
    ± 0.2Hz

     

    Total Harmonic Distortion  (THD-F) 

    Range
    Resolution
    Accuracy
    0.0 – 20%
     
    0.1%
    ± 2%
    20 – 100%
    ± 6% of reading ± 5%
    100 – 999.9 %
    ± 10% of reading ± 10%

      

    General Specifications: Indoors Use 

    PROVA 6830A Analyzer 

    Battery Type:
    1.5V SUM-3 x 8
    External DC Input:      
    Use only power supply adapter Model PHAPSA
    Display:
    Dot Matrix LCD (240x128) with backlight
    LCD Update Rate:
    1 time / second
    Power Consumption:
    140mA (approx.)
    No. Of Samples:
    1024 samples / period
    Data Logging Files:
    85
    Max. File Capacity:
    17474 records (3P4W, 3P3W)
    26210 records (1P3W)
    52420 records (1P2W)
    4096 records (50 Harmonics / record)
    Sampling Time:
    2 to 3000 seconds for data logging
    Low battery Indication:   
     
    Overload Indication:
    OL
    Operating Temperature:
    -10°C to 50°C
    Operating Humidity:
    less than 85% relative
    Storage Temperature:    
    -20°C to 60°C
    Storage Humidity:
    less than 75% relative
    Dimension:
    257 (L) x 155 (W) x 57 (H) mm
    10.1” (L) x 6.1” (W) x 2.3” (H)
    Weight:                       
    1160g (Batteries included)
    Accessories:               
    Probes (model 3006) x 3
    Test leads (3 meter long) x 4
    Alligator clips x 4, Carrying bag x 1
    Users manual x 1, Batteries 1.5V x 8
    AC power adapter x 1, Software CD x 1
    Software users manual x 1
    USB to RS232 cable x 1

     

    AFLEX 3006 Flexible Current Probes 

    Probe Length:   ( 3006-36 )
    36 in / 920 mm
    Minimum Bending Diameter:  
    35mm
    Connector Diameter:  
    23mm
    Cable Diameter:
    14mm
    Cable Length from Probe to Box:   
    1700mm
    Cable Length from Box to Output: 
    1700mm
    Range Selection:        
    Manual (600A, 6000A)
    Battery:                           
    powered by power analyzer
    Dimension (Box):       
    130mm(L) x 80mm(W)x 43mm(H)
    5.1”(L) x 3.1”(W) x 1.7”(H)
    Weight:                           
    430g

     

    Related Products