DC/AC Clamp Meter
- Specification
- Application
Electrical Specifications: (23℃±5℃)
DC Current:
Range |
Resolution |
Accuracy |
Overload Protection |
40A |
10mA |
±1.0%±2dgts |
DC 400A |
0-150A |
100mA |
±1.0%±2dgts |
|
150-200A |
100mA |
±2.2%±2dgts |
AC Current:
Range |
Resolution |
Accuracy |
Overload Protection |
|
50/60 Hz |
40 – 1KHz |
|||
40A |
10mA |
±1.0%±3dgts |
±1.5%±4dgts |
AC 400A |
0-150A |
100mA |
±1.0%±3dgts |
±1.5%±4dgts |
|
150-200A |
100mA |
±2.2%±3dgts |
±2.5%±4dgts |
DC Voltage: (Input Impedance: 10M)
Range |
Resolution |
Accuracy |
Overload Protection |
400V |
0.1V |
±1.0%±2dgts |
DC 1000V |
AC Voltage:(Input Impedance: 10MΩ)
Range |
Resolution |
Accuracy |
Overload Protection |
|
50/60 Hz |
40 – 1KHz |
|||
400V |
0.1V |
±1.5%±2dgts |
±2.0%±4dgts |
AC 800V |
Resistance (Ω) and Continuity: (open voltage 0.4V)
Range |
Resolution |
Accuracy |
Beeping |
Overload Protection |
40-400Ω |
0.1Ω |
±1.0%±2dgts |
< 40.0 Ω (approx.) |
AC 600V |
Frequency: (Auto range)
Range (Hz) |
Resolution |
Accuracy |
Sensitivity |
O.L Protection |
1-100K |
0.001 – 100 |
±0.5%±2dgts |
10V |
AC 600V |
General Specifications:
Conductor Size: |
23mm max. (approx.) |
Dimension (Box): |
183 (L) x 63.6 (W) x 35.6 (H) mm 7.2" (L) x 2.5" (W) x 1.4" (H) |
Battery Type: |
two 1.5V SUM-3 |
Display: |
3 3/4 LCD with 40 seg. bargraph |
Range Selection: |
Manual |
Overload Indication: |
OL |
Power Consumption: |
17 mA (approx.) |
Low Battery Indication: |
|
Sampling Time: |
3 times/sec. (display) 30 times/sec. (bargraph) |
Operating Temperature: |
-10C to 50C |
Operating Humidity: |
less than 85% relative |
Altitude: |
up to 2000M |
Storage Temperature: |
-20C to 60C |
Storage Humidity: |
less than 75% relative |
Weight: |
190g (battery included) |
Accessories: |