Electrical Specifications: (23℃±5℃)
DC Current:
Range |
Resolution |
Accuracy |
Overload Protection |
40A |
10mA |
±1.5%±2dgts |
DC 400A |
0-150A |
100mA |
±1.5%±2dgts |
|
150-200A |
100mA |
±2.2%±2dgts |
AC Current:
Range |
Resolution |
Accuracy |
Overload Protection |
|
50/60 Hz |
40 – 1KHz |
|||
40A |
10mA |
±1.5%±3dgts |
±2.0%±4dgts |
AC 400A |
0-150A |
100mA |
±1.5%±3dgts |
±2.0%±4dgts |
|
150-200A |
100mA |
±2.2%±3dgts |
±2.5%±4dgts |
DC Voltage:(Overload Protection: 600V)
Range |
Resolution |
Accuracy |
Input Impedance |
400mV |
0.1 mV |
±1.5%±3dgts |
2.3MΩ |
4V |
1 mV |
||
40V |
10 mV |
||
400V |
100 mV |
||
600V |
1V |
AC Voltage:(Input Impedance: 2.3 MΩ)
Range |
Resolution |
Accuracy |
Overload Protection |
|
50/60 Hz |
40 – 1KHz |
|||
0.01 - 4V |
1mV |
±1.5%±5dgts |
±2.0%±5dgts |
AC 800V |
40V |
10mV |
|||
400V |
100mV |
|||
600V |
1V |
Frequency:
Range (Hz) |
Resolution (Hz) |
Accuracy |
Sensitivity |
O.L Protection |
1-100K |
0.001–100 |
±0.5%±2dgts |
5V |
AC 600V |
Duty:
Range (<10KHz) |
Resolution |
Accuracy |
Sensitivity |
1 – 99% |
0.1% |
10d |
10V |
Continuity:(Open circuit voltage 0.4V, Overload Protection AC 600V)
Range |
Resolution |
Accuracy |
Beeper |
40-400Ω |
0.1Ω |
±1.0%±2dgts |
<10.0Ω (approx.) |
Resistance (Ω): (Open circuit voltage 0.4V)
Range |
Resolution |
Accuracy |
Overload Protection |
400Ω |
0.1Ω |
±1.5%±2dgts |
AC 600V |
4KΩ |
1Ω |
||
40KΩ |
10Ω |
||
400KΩ |
100Ω |
||
4MΩ |
1KΩ |
||
40MΩ |
10KΩ |
Temperature:(K Type Thermal Couple with Adapter, ℃ or ℉ )
Range |
Resolution |
Accuracy |
Overload Protection |
-40 – 0 ℃ |
0.1 ℃ |
±2.0%±2 ℃ |
AC 600V |
0 – 400 ℃ |
0.1 ℃ |
±0.5%±2 ℃ |
|
400 – 1000 ℃ |
1 ℃ |
±0.5%±2 ℃ |
|
-40 – 0 ℉ |
0.1 ℉ |
±2.0%±4 ℉ |
|
0 – 400 ℉ |
0.1 ℉ |
±0.5%±4 ℉ |
|
400 – 1800 ℉ |
1 ℉ |
±0.5%±4 ℉ |
Capacitance:
Range |
Resolution |
Accuracy |
Overload Protection |
40nF |
10pF |
±5.0%±0.2 nF |
AC 600V |
400nF |
0.1nF |
±3.0%±0.2 nF |
|
4μF |
1nF |
±3.0%±0.02μF |
|
40μF |
10nF |
±3.0%±0.02μF |
|
400μF |
100nF |
±3.0%±0.2μF |
Diode Test:
Range |
Resolution |
Accuracy |
Overload Protection |
0 – 1.999V |
0.001V |
±2.5%±5dgts |
AC 600V |
General Specifications:
Conductor Size: |
23mm max. (approx.) |
Dimension (Box): |
183 (L) x 63.6 (W) x 35.6 (H) mm 7.2" (L) x 2.5" (W) x 1.4" (H) |
Battery Type: |
two 1.5V SUM-3 |
Display: |
3 3/4 LCD with 40 seg. Bargraph |
Range Selection: |
Auto and Manual |
Overload Indication: |
OL |
Power Consumption: |
10 mA (approx.) |
Low Battery Indication: |
|
Sampling Time: |
3 times/sec. (display) 30 times/sec. (bargraph) |
Auto-Power-Off: |
15 minutes |
Operating Temperature: |
-10℃ to 50℃ |
Operating Humidity: |
less than 85% relative |
Altitude: |
up to 2000M |
Storage Temperature: |
-20℃to 60℃ |
Storage Humidity: |
less than 75% relative |
Weight: |
190g (battery included) |
Accessories: |
Adapter (for Capacitance and K-type Thermal Couple) x 1 K-type Thermocouple x 1 Testing leads x 1 Carrying bag x 1 Users manual x 1 1.5V battery x 2 |