Clamp Meter
- Specification
- Application
UL /CE CAT III 600V
Features:
■ Accurate DC/AC digital clamp meter for current measurement
■ DC 2500A, AC 2100A
(Average sensing for PROVA 2003, True RMS for PROVA 2000)
■ DC/AC 600V
■ Analog output for datalogger or oscilloscope
■ 55 mm diameter jaw
■ One touch zero for DCA adjustment
■Auto-range for A, V, , Hz
■ Large 3 3/4 digits LCD
■ Fast bargraph display (30 times/sec.) for transient observation
■ Frequency, Resistance measurement
■ Continuity with buzzer
■ Diode Test
■ Max/Min and Data Hold functions
■ Auto-power-off function
■ 600V overload protection for ohm measurement
■ Easy single rotary switch for any function selection
Electrical Specifications: (23℃±5℃)
DC Current:
Range |
Resolution |
Accuracy (of rdg) |
Overload Protection |
400A |
0.1A |
±1.5%±3dgts |
DC 3000A
|
0-2000A |
1A |
±1.5%±3dgts |
|
2000-2500A |
1A |
±2.0%±3dgts |
AC Current:
(Average Sensing for PROVA 2003, True RMS for PROVA 2000, Crest Factor < 4)
Range |
Resolution |
Accuracy (of rdg) |
Overload Protection |
|
50/60 Hz |
40 – 1KHz |
|||
400A |
0.1A |
±1.5%±5dgts |
±2.0%±5dgts |
AC 3000A
|
0-1000A |
1A |
±2.0%±5dgts |
±2.5%±5dgts |
|
1000-2100A |
1A |
±2.5%±5dgts |
±3.0%±5dgts |
Current Analog Output:
Range |
Output |
Accuracy |
Overload Protection |
0 - 400A |
1mV/A |
±2.5% ±0.5A |
600V AC |
400 - 2100A |
1mV/A |
±2.5% ± 5A |
DC Voltage: (Autorange & Manual, Overload Protection 800VAC for all range)
Range |
Resolution |
Accuracy (of rdg) |
Input Impedance |
400mV |
0.1mV |
±1.5%±3dgts
|
10M |
4V |
0.001V |
5M |
|
40V |
0.01V |
||
400V |
0.1V |
||
600V |
1V |
AC Voltage:
(Average Sensing for PROVA 2003, True RMS for PROVA 2000, Crest Factor<4)
(Autorange & Manual, Overload Protection 800VAC for all range)
Range |
Resolution |
Accuracy (of rdg) |
Input Impedance |
|
50/60 Hz |
40 – 1KHz |
|||
400mV |
0.1mV |
-------- |
--------- |
--------- |
4V |
0.001 |
±1.5%±5dgts |
±2.0%±5dgts |
5M |
40V |
0.01V |
|||
400V |
0.1V |
|||
600V |
1V |
ResistanceΩ : (Autorange & Manual, Open Circuit Voltage 0.5V)
Range |
Resolution |
Accuracy (of rdg) |
Overload Protection |
400Ω |
0.1Ω |
±1.5%±3dgts |
600VAC |
4KΩ |
1Ω |
||
40KΩ |
10Ω |
||
400KΩ |
100Ω |
||
4MΩ |
1KΩ |
||
40MΩ |
10KΩ |
Resistance (Ω) and Continuity: (open voltage 0.4V)
Range |
Resolution |
Accuracy |
Beeping |
OL Protection |
40-400Ω |
0.1Ω |
±1.0% rdg±2dgts |
< 40.0Ω (approx.) |
AC 600V |
Diode Test
Range |
Resolution |
Accuracy |
Overload Protection |
1.999V |
0.001V |
±2.5%±5dgts |
600VAC |
Frequency:
(Hz, Overload Protection 600VAC, Sensitivity selected by RANGE button)
Range |
Resolution |
Accuracy |
Sensitivity |
1Hz - 400KHz |
0.001Hz - 100Hz |
±0.5%±2dgts |
10V |
General Specifications:
Conductor Size: |
Cable 55mm. (approx.) |
Battery Type: |
9V |
Display: |
3 3/4 LCD with 40 seg. bargraph |
Range Selection: |
Auto and Manual |
Overload Indication: |
OL |
Power Consumption: |
17 mA(approx.) |
Low battery Indication: |
|
Sampling Time: |
3 times/sec. (display) 30 times/sec. (bargraph) |
Operating Temperature: |
4°C to 50°C |
Operating Humidity: |
less than 85% relative |
Altitude: |
up to 2000M |
Storage Temperature: |
-20°C to 60°C |
Storage Humidity: |
less than 75% relative |
Dimension: |
271mm (L) x 112mm (W) x 46mm (H) 10.7" (L) x 4.4" (W) x 1.8" (H) |
Weight: |
647g / 22.8 oz (battery included) |
Accessories: |
Carrying bag x 1 Users manual x 1 Batteries 9V x 1 Testing leads |