PROVA-6200
Graphic Power Quality Analyzer
Availability: In stock
Analysis for Single Phase and Balanced 3 phase system. True RMS Value (V and I). Active Power (K,KW,MW,GW). Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR). Power Factor (PF), Phase Angle( Φ ). Energy (WH,KWH,KVARH,PFH). Programmable PT(1 to 3000)Ratios. Display of Overlapped Voltage and Current Waveform. Maximum Demand (MD in W,KW,MW) with programmable Period. Harmonic Analysis (V and I) to 50th Order. Display of 25 Harmonics in one screen. Optical Isolated RS-232C Interface. Smart Datalogging to save Battery. Datalogging of 32,64,128 or 256 points/cycles. Analysis of Total Harmonic Distortion (%THD-F). Graphic Phasor Diagram. Capture 128 Transient Events (Time+Cycles+Faults) with Programmable Threshold(%),also can be reviewed in LCD. 50000 Records with Programmable Interval (1 to 6000 seconds). Real-time Output of Waveform, Power Parameters and Harmonics at Command. Large Dot Matrix LCD Display with Backlight. Power for Long-term Monitoring. Built -in Calendar Clock for Data Logging.
- Specification
- Application
AC Current (50 or 60 Hz, Auto Range, True RMS) |
Range
|
Resolution
|
Accuracy of Reading
|
4.0 V - 1500.0 A
|
0.01 A
|
± 0.5 % ± 5 dgts
|
|
AC Voltage (50 or 60 Hz, Auto Range, True RMS)
|
Range
|
Resolution
|
Accuracy of Reading
|
4.0 - 600.0 V
|
0.1 V
|
± 0.5 % ± 5 dgts
|
|
Harmonics of AC Voltage in Percentage and Magniude(1 to 50th order)
|
Range
|
Resolution
|
Accuracy (in%)
|
|
1 – 20 th
|
0.1 %
|
± 2 %
|
± 2 % ± 0.5 V
|
20 – 50 th
|
0.1 %
|
4 % of reading ± 2 %
|
4 % of reading ± 0.5 V
|
|
Harmonics of AC Current in Percentage and Magnitude (1 to 50th order)
|
Range
|
Resolution
|
Accuracy (in %)
|
|
1 – 20 th
|
0.1 %
|
± 2 %
|
± 2 % of reading ± 0.4 A
|
20 – 50 th
|
0.1 %
|
4 % of reading ± 2 %
|
± 4 % of reading ± 0.4A
|
|
Range
|
Resolution
|
Accuracy (>20 V and >20 A)
|
0.000 - 1.000
|
0.001
|
± 0.04
|
|
Range
|
Resolution
|
Accuracy (>20 V and >20 A)
|
-180 ° to 180 ° (0 ° to 360 ° )
|
0.1 °
|
±1 °
|
|
Total Harmonic Distortion(%THD-F,1 to 50th order)
|
Range
|
Resolution
|
Accuracy (>20 V and >20 A)
|
0.0 - 20%
|
0.1%
|
± 2 %
|
20 - 100%
|
0.1%
|
± 6 % of reading ± 1 %
|
100 - 999.9%
|
0.1%
|
± 10 % of reading ± 1 %
|
|
Range
|
Resolution
|
Accuracy of Readings
|
1.00 - 99.99
|
0.01
|
± 5 % ± 30 digits
|
|
AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1)
|
Range
|
Resolution
|
Accuracy of Readings
(>20V and >20A)
|
10.0 - 999.9 W
|
0.1 W
|
± 1% ± 20 dgts
|
1.00 - 9.999 KW
|
0.001 KW
|
± 1% ± 20 dgts
|
10.00 - 99.99KW
|
0.01 KW
|
± 1% ± 20 dgts
|
100.0 - 999.9 KW
|
0.1 KW
|
± 1% ± 20 dgts
|
1000 - 9999 KW
|
1 KW
|
± 1% ± 20 dgts
|
|
Conductor Size |
55mm(approx.), 64*24mm(bus bar) |
Battery Type |
Two 1.5 V SUM-3 |
Display |
128*64 Dot Matrix |
Power Consumption |
10 mA (approx.) |
Auto - Power - Off |
30 minutes after power-on |
Update time |
2 times/sec. (display) |
No. of Samples per Period |
512 (voltage or current),256 (power) |
Operating Temperature |
-10 ℃ to 50 ℃ |
Operating Humidity |
<85% RH |
Storage temperature |
-20 ℃ to 60 ℃ |
Storage Humidity |
<75% RH |
Dimension |
210 mm (L) * 62 mm (W) * 35.6 mm (H),8.3"(L) * 2.5 "(W) * 1.4"(H) |
Weight |
Test leads *1 pair, Carrying bag*1, Users manual*1, Batteries 1.5V*2 |
Accessories |
640g |
|