Electrical Specifications: (23℃±5℃)
Ground Resistance (Auto range):
Range |
Resolution |
Accuracy of Reading1 |
0.025 - 0.250 |
0.002 |
± 1.5% ± 0.05 |
0.251 - 1.000 |
0.02 |
± 1.5% ± 0.05 |
1.001 – 10.00 |
0.02 |
± 1.5% ± 0.1 |
10.01 - 50.00 |
0.04 |
±2.0% ± 0.3 |
50.01 – 100.0 |
0.04 |
±2.0% ± 0.5 |
100.1 - 200.0 |
0.4 |
± 3.0% ± 1.0 |
200.1 - 400.0 |
2 |
± 5.0% ± 5 |
400.1 - 600.0 |
5 |
± 10% ± 10 |
600.1 – 1500 |
20 |
± 20% |
1 Loop resistance noninductive, external field < 50 A/m, external electrical field < 1 V/m, conductor centered.
2 Resistance Measurement Frequency: 3.333KHz
High and Low Alarm
|
Range |
Resolution |
High Alarm |
0 - 1510 |
1 |
Lo Alarm |
0 - 1510 |
1 |
Ground/ Leakage Current (Auto range, 50/60 Hz, True RMS, Crest Factor < 3.0)
Range |
Resolution |
Accuracy of Reading |
0.300 - 1.000 mA |
0.001 mA |
± 2.0% ± 0.05 mA |
1.00 - 10.00 mA |
0.01 mA |
± 2.0% ± 0.03 mA |
10.0 - 100.0 mA |
0.1 mA |
± 2.0% ± 0.3 mA |
100 – 1000 mA |
1 mA |
± 2.0% ± 3 mA |
Ground/ Leakage Current (50/60 Hz, True RMS, Crest Factor < 3.0)
Range |
Resolution |
Accuracy of Reading |
0.200 – 4.000 A |
0.001 A |
± 2.0% ± 0.03 A |
4.00 – 30.00 A |
0.01 A |
± 3.0% ± 0.03 A |
Accuracy of Resistance Calibration Plate: ±1%
Data Logging Capacity:116 records
Data Logging Interval: 1 to 255 seconds
General Specifications:
Conductor Size: |
23 mm (0.9”) approx. (5601) 35 mm (1.38") (5637) |
Jaw Opening: |
27 mm (1.06”) approx. (5601) 38 mm (1.49") (5637) |
Dimension: |
257mm (L) x 100mm(W) x 47mm(H) 10.1" (L) x 3.9"(W) x 1.9"(H) 276mm (L) x 100mm(W) x 47mm(H)
10.8" (L) x 3.9"(W) x 1.9"(H) |
Battery Type: |
9V IEC 6 LR61 (Alkaline) |
Display: |
4 digits 9999 counts LCD |
Range Selection: |
Auto |
Auto-Power-Off: |
About 4~6 minutes |
Overload Protection: |
100A (continuous); 200A (5 sec.) |
Overload Indication: |
OL |
Power Consumption: |
40mA |
Low Battery Indication: |
|
Battery Life: |
3000 measurements |
Sampling Time: |
0.5 seconds (5601) 20 times / seconds (5637) |
Operating Temperature: |
0C to 50C (14F to 122 F) |
Operating Humidity: |
less than 85% relative |
Altitude: |
up to 2000M |
Storage Temperature: |
-20C to 60C (-4F to 122 F) |
Storage Humidity: |
less than 75% relative |
Temperature Coefficient:
|
0.1% x (Specified Spec.) / ℃ (<18℃ or >28℃) |
Weight: |
640g / 1.4 lbs (5601) 750g / 1.65lbs (5637) |
Accessories: |
Resistance Calibration Plate x 1 9V Battery (Installed) x 1 Users Manual x 1 Carrying Case x 1 |
l Telecommunication
l Electrical Power Plant
l Factory and Facility
l Cable TV System
l Cellular Phone System
l Gas Station & Tank
-
PROVA-5637 Clamp-on Ground Resistance Tester‧Non-Contact Ground Resistance Measurement
‧No Auxiliary Electrode Needed
‧Ground Resistance Measurement: 0.025 – 1500Ω
‧Leakage Current: 0.3mA – 30A, True RMS (5601)
‧Leakage Current: 0.3mA – 35A, True RMS (5637)
‧Jaw Diameter: 23mm (5601)
‧Jaw Diameter: 35mm (5637)
‧Programmable High and Low Alarm
‧Data logging capacity: 116 records
‧Programmable Data Logging: data logging interval 1 to 255 sec.
‧Auto-power-off function
- US$ 1045
- Log in for sale price
-
TES-1700 Digital Earth Tester‧Capable of measuring earth voltage.
‧Data hold , MAX / MIN function.
‧Auto power off function:
The timer operates automatically about 3 minutes when the " Test Button Switch " are pressed to keep the tester power on.
‧2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
‧In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.(unit can be hung from the neck for simplified measurement).
‧Automatic warning when resistance of auxiliary earth. Spikes is in excess of tolerance.
‧Designed to meet IEC1010-1 safety standard.
‧Zero ohm adjustment- US$ 215
- Log in for sale price
-
TES-1605 Digital Earth Tester‧Capable of measuring earth voltage.
‧Data hold function.
‧Auto power off function:
The timer operates automatically about 10 minutes when the “ Test Button Switch ”are pressed to keep the tester power on.
‧2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
‧In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.
‧Automatic warning when resistance of auxiliary earth spike is in excess of tolerance.
‧Designed to meet EN 61010-1/ / EN 61557 safety standard.
‧Zero ohm adjustment.
- US$ 155