TES-3910

Trms Clamp Meter (DC/AC 1000A)

Availability: In stock
  • Capacitance measurement 1000µF.
  • Variable-frequency drive (VFD) V & Hz measurement.
  • Lo-Z voltage measurement to drain ghost voltages.
  • Check 3Φ phase sequence.
  • True RMS reading on AC and DC+AC mode.
  • Inrush current measurement.
  • A measurement for HVAC flame sensors.
  • mV measurement range to interface with other accessories.
  • Crest Factor & Harmonic ratio measurement.
  • Data hold, Auto hold & Peak hold mode.
  • Max/Min/Avg record mode.
  • Data memory & read function.
    • Shipping
    • Payments
    • Quantity
    • US$ 127Log in for sale price
    To show price, please join membership and log in.
    Trms Clamp Meter (DC/AC 1000A)
    Trms Clamp Meter (DC/AC 1000A)
    • Specification
    • Application

    ELECTRICAL SPECIFICATIONS (23±5)

    AC Current (40Hz to 400Hz) : VFD Trms

    Range

    Resolution

    Accuracy

    Sensitivity

    Overload Protection

    99.99A

    10mA

    ±2%±20dgts (50, 60Hz)

     ±4%±20dgts (40~400Hz)

    >0.25A

    1000A AC

    999.9A

    100mA

    >2.5A

    DC Current :

    Range

    Resolution

    Accuracy

    Sensitivity

    Overload Protection

    99.99A

    10mA

    ±2% ±20dgts

    >0.25A

    1000A

    999.9A

    100mA

    >2.5A

    ACA Inrush Current : VFD Trms

    Range

    Resolution

    Sensitivity

    Measurement Time

    Overload Protection

    99.99A

    0.01A

    >5A

    100mS

    1000AAC

    999.9A

    0.1A

    >50A

    DCμA : (Burden Voltage : 3.6mV/μA)

    Range

    Resolution

    Accuracy

    Sensitivity

    Overload Protection

    99.99μA

    10nA

    ±1% ±20dgts

    >0.30μA

    1000V

    999.9μA

    100nA

    >3.0μA

    ACμA : VFD Trms (Burden Voltage : 3.6mV/μA)

    Range

    Resolution

    Accuracy

    Sensitivity

    Overload Protection

    99.99μA

    10nA

    ±1%±10dgts (50, 60Hz)

    ±2%±10dgts (40~400Hz)

    >0.30μA

    1000V

    999.9μA

    100nA

    >3.0μA

    AC Voltage (40Hz to 400Hz) : VFD Trms

    Range

    Resolution

    Accuracy

    Sensitivity

    Overload Protection

    999.9mV

    0.1mV

    ±1%±10dgts (50, 60Hz)

    ±2%±10dgts (40~400Hz)

    40 ~ 300Hz on mV range

    >2mV

    1000V

    9.999V

    1mV

    >20mV

    99.99V

    10mV

    >200mV

    999.9V

      100mV

    >2V

    DC Voltage

    Range

    Resolution

    Accuracy

    Sensitivity

    Overload Protection

    999.9mV

    0.1mV

    ±1% ±20dgts

    >2mV

    1000V

    9.999V

    1mV

    >20mV

    99.99V

    10mV

    >200mV

    999.9V

      100mV

    >2V

    Resistance (Continuity<40Ω on the range) :

    Range

    Resolution

    Accuracy

    Overload Protection

    999.9Ω

    100mΩ

    ±1% ±10dgts

    1000V

    9.999KΩ

    1Ω

    99.99KΩ

    10Ω

    999.9KΩ

    100Ω

    3ΦPhase sequence indication :

    Range

    Frequency Response

    Overload Protection

    80V to 480V

    50Hz / 60Hz

    1000V

    Diode (Continuity<40mV) :

    Range

    Resolution

    Accuracy

    Overload Protection

    3.000V

    1mV

    ±1% ±10dgt

    1000V

    Frequency :

    Range

    Resolution

    Accuracy

    Sensitivity

    40Hz/1KHz

    0.1Hz

    ±0.5%rdg ±2dgts

      V > 5% range

    μA, A > 30%

    Capacitance:

    Range

    Resolution

    Accuracy

    Overload Protection

    1.000μF

    1nF

    ±1.5%±5dgts

    1000V

    10.00μF

    10nF

    100.0μF

    100nF

    1000μF

    1μF


    GENERAL SPECIFICATIONS :

    Accessories : Instruction Manual, Battery, Carrying case & Test Lead

    Weight/Size : 236(L)x80(W)x39(T)mm/332g

    Max Wire Diameter : 33mm

    Category : CAT III 1000V, CAT IV 600V

     

    Related Products