TES-2712

DIGITAL MULTIMETER

Availability: In stock
  • 3 1/2 LCD.
  • Data-hold and peak-hold function available.
  • Inductance, Capacitance & ohm measurement.
    • Shipping
    • Payments
    • Quantity
    • US$ 77Log in for sale price
    To show price, please join membership and log in.
    DIGITAL MULTIMETER
    DIGITAL MULTIMETER
    • Specification
    • Application

    Electrical Specifications :

    Accuracies aqre ± (…% of reading + …digits) at 23± 5 and below 80% RH.

     

    DC Voltage :

    Range

    Resolution

    Accuracy

    Input Impedance

    Overload Protection

    200mV

    0.1mV

    0.5%+1

    10MΩ

    600Vrms

    2V

    1mV

    750Vpp

    20V

    10mV

    200V

    100mV

    600V

    1V

    0.5%+2

     

    AC Voltage : 50Hz500Hz

    Range

    Resolution

    Accuracy

    Input Impedance

    Overload Protection

    200mV

    0.1mV

    1%+5

    10MΩ

    600Vrms

    2V

    1mV

    750Vpp

    20V

    10mV

    200V

    100mV

    600V

    1V

    1.2%+5

     

    DC Current :

     Range

    Resolution

    Accuracy

    Burden Voltage

    Overload Protection

    200uA

    0.1uA

    1%+1

    0.35V

    0.5A/250V fast blow fuse & Diode

    2mA

    1uA

    20mA

    10uA

    200mA

    100uA

    20A

    10mA

    1.2%+3

    0.8V

    20A/380V fast blow fuse
    10A Continuity 
    20A for 30 sec. max.

     

    AC Current : 50Hz500Hz

    Range

    Resolution

    Accuracy

    Burden Voltage

    Overload Protection

    200uA

    0.1uA

    1.2%+3

    0.35V

    0.5A/250V fast blow fuse & Diode

    2mA

    1uA

    20mA

    10uA

    200mA

    100uA

    20A

    10mA

    1.5%+3

    0.8V

    20A/380V fast blow fuse
    10A Continuity 
    20A for 30 sec. max.

     

    Resistance:

    Range

    Resolution

    Accuracy

    Open Circuit Voltage

    Overhead protection

    200Ω

    0.1Ω

    0.8%+ 2

    3.2V

    600Vrms

    2KΩ

    1Ω

    0.5V

    20KΩ

    10Ω

    200KΩ

    100Ω

    2MΩ

    1KΩ

    20MΩ

    10KΩ

    1.5%+ 3

     

    Diode Test: ()

    Range

    Resolution

    Accuracy

    Open Circuit Voltage

    Text Current

    Overload Protection

     

    1mV

    2%+ 2

    3.2V

    1.0mA

    660Vrms

     

    Audible Continuity:

    Range

    Resolution

    Max Open Circuit Voltage

    Overload Protection

     

    20Ω

    3.2V

    660Vrms

     

    Frequency ( Hz )( Test Range 10Hz - 10MHz Auto Range )

    Range

    Resolution

    Accuracy

    Max. Open Circuit Voltage

    Overload Protection

    2KHz

    1Hz

    0.5%+2

    1.5Vrms

    600Vrms

    20KHz

    10Hz

    200KHz

    100Hz

    2MHz

    1KHz

    10MHz

    10KHz

    3Vrms

     

    Inductance(The accuracy is based on when “Q” value is greater than 1)

    Range

    Resolution

    Accuracy

    Test Frequency

    20mH

    10uH

    5% + 10

    200Hz

    200mH

    100uH

    2H

    1mH

    20H

    10mH

     

    Capacitance (F)

    Range

    Resolution

    Accuracy

    Test Frequency

    2000pF

    1PF

    3% + 10

    200Hz

    200nF

    100PF

    2uF

    1nF

    20uF

    10nF

     

     

    B: Peak Hold Measurement (Capture and retain elusive voltage or variant surge long enough for reading)

    DC Voltage :

    Range

    Resolution

    Accuracy

    Input Impedance

    Overload Protection

    200mV

    0.1mV

    1%+2

    10MΩ

    600Vrms

    2V

    1mV

    750Vpp

    20V

    10mV

    200V

    100mV

    600V

    1V

     

    AC Voltage : 50Hz500Hz

    Range

    Resolution

    Accuracy

    Input Impedance

    Overload Protection

    200mV

    0.1mV

    1.8%+7

    10MΩ

    600Vrms

    2V

    1mV

    750Vpp

    20V

    10mV

    200V

    100mV

    600V

    1V

     

    DC Current :

    Range

    Resolution

    Accuracy

    Burden Voltage

    Overload Protection

    200uA

    0.1uA

    1.5%+2

    0.35V

    0.5A/250V fast blow fuse & Diode

    2mA

    1uA

    20mA

    10uA

    200mA

    100uA

    20A

    10mA

    1.8%+2

    0.8V

    20A/380V fast blow fuse
    10A Continuity 
    20A for 30 sec. max.

     

    AC Current : 50Hz500Hz 

    Range

    Resolution

    Accuracy

    Burden Voltage

    Overload Protection

    200uA

    0.1uA

    2%+5

    0.35V

    0.5A/250V fast blow fuse & Diode

    2mA

    1uA

    20mA

    10uA

    200mA

    100uA

    20A

    10mA

    2.5%+8

    0.8V

    20A/380V fast blow fuse
    10A Continuity 
    20A for 30 sec. max.

     

    General Specifications :

    1.    Numerical Display : 3-1/2 digit liquid crystal display (LCD) maximum reading 1999 and Bargraph indication.

    2.    Palarity : Automatic “ -” negative polarity indication.

    3.     Overrange :  “OL” appears on the display.

    4.    Sampling Rate : 2.5 readings per second.

    5.    Power : JIS006P. 9-Volt battery, NEDA1604, IEC6F22 or JIS006P.

    6.    Operating Storage Temperature and Humidity :  0 to 40, below 80% RH / -10 to 60, below70% RH.

    7.    Dimensions : 180(L) x 82(W) x 38(H)mm

    8.    Weight : 365 g.

    9.    Accessories : Test leads, Spare fuse (0.5A/250V), Battery, Operating Instruction.

     

     