PROVA-903

Digital Multi-Meter

Availability: In stock
  • 60,000 counts and dual input channels.
  • 0.03% DC voltage basic accuracy and 0.1% AC voltage basic accuracy.
  • Bandwidth of 200KHz (max.), and True RMS.
  • Fast ACV, ACA response.
  • Better AC accuracy than that of a bench-top DMM.
  • More functions than those of a bench-top DMM.
  • Much lower cost than that of a bench-top DMM.
  • Study the relationship of two voltages similar to a dual channels DSO.
  • Study of relationship of voltage and current with one DMM.
  • Dual display of frequency and duty cycle.
  • Record data of both channels using a PC through the RS-232C interface.
  • PROVA 903: Standalone data logging of 10708 records for both channels.
    • Shipping
    • Payments
    • Quantity
    • US$ 413Log in for sale price
    To show price, please join membership and log in.
    Digital Multi-Meter
    Digital Multi-Meter
    • Specification
    • Application

     

    Electrical Specifications: (23±5)    
    The following accuracy is specified for one single channel (channel 1 or channel 2).   
     If dual channels are used at the same time, additional % of accuracy should be added to the listed accuracy.  
    Please refer to the supplemental dual channels specification.      
    The following accuracy is also specified for the ZEROED (relative) value.   
     The accuracy is given as ±% of reading ± number of least significant digits.  
    AC Voltage:        
    Range (ACV) Resolution Accuracy (50/ 60Hz) Accuracy (45Hz – 1KHz)  
    60.000mV 0.001mV ±0.1%±20dgts ±0.3%±20dgts  
    600.00mV 0.01mV ±0.1%±20dgts ±0.3%±20dgts  
    6.0000V 0.0001V ±0.1%±20dgts ±0.3%±20dgts  
    60.000V 0.001V ±0.1%±20dgts ±0.6%±20dgts  
    600.00V 0.01V ±0.1%±20dgts ±0.6%±20dgts  
    1000.0V (0-400V) 0.1V ±0.1%±20dgts ±2%±30dgts  
    1000.0V (400-1000V) 0.1V ±0.1%±20dgts (45Hz – 400Hz) ±2%±30dgts  
             
    Range  Accuracy  Accuracy  Accuracy   
    (ACV) (20Hz - 45Hz) (1KHz– 10KHz) (10KHz– 20KHz)  
    60.000mV ±0.8%±25dgts ±2%±20dgts ±2.5%±20dgts  
    600.00mV ±0.8%±25dgts ±1%±20dgts ±2.5%±20dgts  
    6.0000V ±0.8%±25dgts ±1%±20dgts ±2.0%±20dgts  
    60.000V ±0.8%±25dgts ±1%±20dgts ±2.0%±20dgts  
    600.00V (0-400V) ±0.8%±25dgts ±5%±20dgts Not Specified  
    600.00V (400-600V) ±0.8%±25dgts Not Specified Not Specified  
    1000.0V (0-400V) ±0.8%±25dgts ±2%±40dgts Not Specified  
    1000.0V (400-1000V) ±0.8%±25dgts Not Specified Not Specified  
             
    Range Accuracy Accuracy Accuracy  
    (ACV) (20KHz – 50KHz) (50KHz– 100KHz) (100KHz-200KHz)  
    60.000mV ±4%±40dgts ±4%±40dgts Not Specified  
    600.00mV ±2%±40dgts ±2%±40dgts ±2%±40dgts  
    6.0000V ±2%±40dgts ±2%±40dgts ±2%±40dgts  
    60.000V ±4%±40dgts ±4%±40dgts Not Specified  
    600.00V Not Specified Not Specified Not Specified  
    1000.0V Not Specified Not Specified Not Specified  
             
    DC Voltage: (Input Impedance: 10M*)      
    Range Resolution Accuracy Overload Protection  
    60.000mV 0.001mV ±0.1%±5dgts DC 1000V  
    600.00mV 0.01mV ±0.03%±3dgts DC 1000V  
    6.0000V 0.0001V ±0.03%±3dgts DC 1000V  
    60.000V 0.001V ±0.03%±3dgts DC 1000V  
    600.00V 0.01V ±0.03%±3dgts DC 1000V  
    1000.0V 0.1V ±0.04%±3dgts DC 1000V  
             
    AC Current:          
    Range (ACA) Resolution Accuracy (50/60Hz) Accuracy (45Hz – 1KHz)  
    600.00μA 0.01μA ±0.3%±20dgts ±0.4%±20dgts  
    6000.0μA 0.1μA ±0.3%±20dgts ±0.4%±20dgts  
    60.000mA 0.001mA ±0.3%±20dgts ±0.4%±20dgts  
    600.00mA 0.01mA ±0.3%±20dgts ±0.4%±20dgts  
    1.0000A 0.0001A ±0.3%±20dgts ±0.4%±20dgts  
    10.000A 0.001A ±0.5%±20dgts ±0.4%±20dgts  
             
    Range (ACA) Accuracy Accuracy Accuracy  
    (20Hz - 45Hz) (1KHz – 10KHz) (10KHz – 20KHz)  
    600.00μA ±1%±20dgts ±2%±20dgts ±1%±20dgts  
    6000.0μA ±1%±20dgts ±2%±20dgts ±1%±20dgts  
    60.000mA ±1%±20dgts ±0.5%±20dgts ±1%±20dgts  
    600.00mA ±1%±20dgts ±0.5%±20dgts ±1%±20dgts  
    1.0000A ±1%±20dgts ±1.5%±20dgts Not Specified  
    10.000A ±2%±20dgts ±1.5%±20dgts Not Specified  
             
    DC Current:        
    Range Resolution Accuracy    
    600.00μA 0.01μA ±0.2%±10dgts    
    6000.0μA 0.1μA ±0.1%±10dgts    
    60.000mA 0.001mA ±0.2%±10dgts    
    600.00mA 0.01mA ±0.1%±10dgts    
    1.0000A 0.0001A ±0.1%±10dgts    
    10.000A 0.001A ±0.3%±10dgts    
             
    Supplemental Dual Channels Specification (DC–400Hz):  
    The following accuracy should be added to all the listed accuracy if dual channels measurements are performed.
      ACV (Ch2) DCV (Ch2) ACA (Ch2) DCA (Ch2)
    ACV ±1%  ±0.5%  ±0.1μA/ V (μA,Ch2) ±0.25%
    (Ch1) ± (V1 – V2) ± (V1 – V2) ±1μA / V (mA,Ch2) (Ch1, Ch2)
      * 200 PPM  * 20 PPM ±0.2mA / V (A, Ch2)  
      (Ch1, Ch2) (Ch1, Ch2) ±2mV / A (mV, Ch1)  
          ±5mV / A (V, Ch1)  
    DCV ±0.5% ± (V1 – V2) ±0.25% ±0.25% ±0.25%
    (Ch1)  * 20 PPM (Ch1, Ch2) (Ch1, Ch2) (Ch1, Ch2)
      (Ch1, Ch2)      
    The result of (V1-V2) * PPM is of volts.      
    V1: the voltage reading in volts of channel 1      
    V2: the voltage reading in volts of channel 2      
    PPM: parts per million, Ch1: Channel 1, Ch2: Channel2    
             
     Resistance: (Ω)        
    Range Resolution Accuracy Overload Protection  
      999.99Ω 0.01Ω ±0.19%±8dgts AC 1000V  
    9.9999KΩ 0.0001KΩ ±0.39%±3dgts AC 1000V  
    99.999KΩ 0.001KΩ ±0.39%±3dgts AC 1000V  
    999.99KΩ 0.01KΩ ±0.19%±3dgts AC 1000V  
    9.9999MΩ 0.0001MΩ ±0.2%±6dgts AC 1000V  
    40.000MΩ 0.001MΩ ±1%±6dgts AC 1000V  
             
    Continuity(        ): 
     (open voltage 3V approx.)    
    Range Resolution Beeper Overload Protection  
    999.99Ω 0.01Ω < 40Ωapprox. AC 1000V  
             
    Capacitance:(       )
     ( auto range, and for film capacitor or better)  
    Range Resolution Accuracy    
      60.00nF 0.01nF ±0.8%±5dgts    
    600.0nF 0.1nF ±1.5%±5dgts    
    6.000μF 0.001μF ±1.5%±5dgts    
    60.00μF 0.01μF ±2.0%±5dgts    
    490.0μF 0.1μF ±3.5%±5dgts    
             
    Capacitance:(       ) 
    (manual range, and for film capacitor or better)    
    Range Resolution Accuracy    
    99.99nF 0.01nF ±0.8%±5dgts    
    999.9nF 0.1nF ±1.5%±5dgts    
    9.999μF 1μF ±1.5%±5dgts    
    99.99μF 0.01μF ±2.0%±5dgts    
    999.9μF 0.1μF ±3.5%±5dgts    
             
     Diode Test:Diodeopen voltage 3V approx., overload protection AC 1000V  
    Range Resolution Accuracy Short Circuit Current  
    3.0000V 0.0001V ±2%±5dgts 0.8 mA typical  
             
    Frequency:TTL        
    Range (Auto) Resolution Accuracy Overload Protection  
    1.000Hz – 2MHz 0.0001Hz–0.0001MHz ±0.005%±4dgts AC 1000V  
             
    Duty Cycle(%, TTL, 1Hz – 600KHz)      
    Range Resolution Accuracy Overload Protection  
    0.001% - 9.999% 0.00% ±30d/KHz±30dgts AC 1000V  
    10.00% – 100.00% 0.01% ±3d/KHz±3dgts AC 1000V  
             
    Frequency: (AC sine wave)      
    Range Resolution Accuracy Overload Protection  
    1.0000Hz– 200KHz 0.0001Hz–100Hz ±0.02%±4dgts AC 1000V  
             
    Duty Cycle: (%, Sine Wave)      
    Range Resolution Accuracy Overload Protection  
    0.001% – 100.00% 0.001% – 0.01% Not specified AC 1000V  
             
    General Specifications:      
    Battery Type: 9V     
    Fuse:  Fast 20A/1000V (A terminal)    
    Fast 1A/1000V (mA / μA terminal)    
    Display: 5 + 5 digits LCD    
    with 30 segments bar graph     
    Range Selection: auto and manual    
    Overload Indication: OL    
    Power Consumption: 6 mA(approx.)    
    Low battery Indication:
     
       
    Operating Temperature: -10C to 40C    
    Operating Humidity: less than 85% relative    
    Altitude: up to 2000M    
    Storage Temperature: -20C to 60C    
    Storage Humidity: less than 75% relative    
    Dimension: 207mm(L) x 101mm (W) x 47mm (H)    
    8.15" (L) x 4" (W) x 1.85" (H)    
    Weight: 430g / 15.2oz (battery included)    
    Accessories: Users manual x 1, 9V battery x 1,     
    USB to RS-232 cable x 1    
    Software CD x 1, Software manual x 1    

     