Digital Clamp Meter
- Specification
- Application
ELECTRICAL SPECIFICATION:
AC Current
Range |
Resolution |
Accuracy (50Hz/60Hz) |
Overload Protection |
20A |
10mA |
±(2%rdg + 5dgts) |
1000A (Within 30 seconds) |
200A |
100mA |
||
1000A |
1A |
DC Voltage
Range |
Resolution |
Accuracy |
Input Impedance |
Overload Protection |
600V |
1V |
±(0.8%rdg + 2dgt) |
10MΩ |
600V |
AC Voltage
Range |
Resolution |
Accuracy (40Hz-400Hz) |
Input Impedance |
Overload Protection |
200V |
100mV |
±(1.2%rdg + 3dgts) |
10MΩ |
600V |
600V |
1V |
Resistance (Ω)
Range |
Resolution |
Accuracy
|
Max. Open Circuit Voltage
|
Overload Protection |
200Ω |
100mΩ |
±(1%rdg + 2dgts) |
3.5V |
600V |
20KΩ |
10Ω |
0.3V |
Frequency (Hz) (10Hz-2KHz)
Range |
Resolution |
Accuracy |
Max. Input Sensitivity
|
Max. Allowable Applied Voltage
|
2KHz |
1Hz |
±(1%rdg + 2dgts)
|
100mV
|
600V |
Diode ()
Range
|
Resolution
|
Max. Test Current
|
Max. Open Circuit Voltage
|
Over Voltage Protection
|
1mV
|
1.5mA
|
3.5V
|
600V
|
Continuity ()
Range
|
Resolution
|
Operation Resistance
|
Max. Open Circuit Voltage
|
Over Protection
|
0.1Ω |
Below 100Ω |
3.5V |
600V |
Peak Hold Measurement (23℃±5℃Below 80% RH)
AC Current
Range |
Resolution |
Accuracy (50Hz 60Hz) |
Overload Protection
|
20A |
10mA |
±(2%rdg + 10dgts) |
1000A
(Within 30 seconds)
|
200A |
100mA |
||
600A |
1A |
AC Voltage
Range
|
Resolution
|
Accuracy (50Hz 60Hz) |
Input Impedance
|
Overload Protection
|
200V
|
100mV
|
±(1.5%rdg + 8dgts)
|
10MΩ |
600V
|
600V
|
1V
|
GENERAL SPECIFICATION:
•Operating Temperature: 0℃~40℃, 0-80% RH.
•Sampling Rate: 2.5 times per second.
•The time of peak Value Response: about 100ms.
•Power Source: 006P DC 9V 1pc.
•Size & Weight: 208mm×65mm×31mm & 308g.
•Accessories: Test probe 1 pair, Instruction Manual, Carrying Case, Battery.