Electrical Specifications: (23℃±5℃)
AC Watt
Range
(0 to 3000A)
|
Resolution
|
Accuracy of Readings
|
> 20 V and > 30A
|
< 20V or < 30A
|
10.0 – 999.9 W
|
0.1W
|
±1% of range
|
±2% of range
|
1.000 – 9.999 KW
|
0.001 KW
|
10.00 – 99.99 KW
|
0.01 KW
|
100.0 – 999.9 KW
|
0.1 KW
|
1000 – 9999 KW
|
1 KW
|
Range of CT (Current Transformer) Ratio: 1 to 600
AC Apparent Power (VA, from 0.000 VA to 9999 KVA): VA = V r.m.s. x A r.m.s
AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR): VAR = √(VA2 – W2)
AC Active Energy (mWH, WH, or KWH, from 0mWH to 999,999KWH): WH = W * Time (in hours)
AC Current (Auto range, TRMS, Overload Protection AC 3000A)
Range
|
Resolution
|
Accuracy of Readings
|
10.0 – 300.0A
|
0.01A / 0.1A
|
±1% of range
|
300.0 – 3000A
|
0.1A / 1A
|
AC Voltage (Auto range, TRMS, Overload Protection AC 800V)
Range
|
Resolution
|
Accuracy of Readings
|
20.0 V – 500.0 V (Phase to Neutral)
|
0.1 V
|
±0.5% ± 5dgts
|
20.0 V – 600.0 V (Phase to Phase)
|
Range of VT (Voltage Transformer) Ratio: 1 to 3000
Harmonics of AC Voltage in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2%
|
21 – 49th
|
±4% of reading ± 2.0%
|
50 – 99th
|
±6% of reading ± 2.0%
|
Harmonics of AC Voltage in Magnitude
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1V
|
±2% ± 0.5V
|
21 – 49th
|
±4% of reading ± 0.5V
|
50 – 99th
|
±6% of reading ± 0.5V
|
Peak Value of ACV (peak value > 20V) or ACA (peak value > 30A), VT=1
Range
|
Sampling Time
|
Accuracy of Reading
|
50 Hz
|
19μs
|
± 5% ± 30 digits
|
60 Hz
|
16μs
|
Crest Factor (C.F.) of ACV (peak value >20V) or ACA (peak value > 30A), VT=1
Range
|
Resolution
|
Accuracy of Readings
|
1.00 – 99.99
|
0.01
|
± 5% ± 30 digits
|
Harmonics of AC Current in Percentage
Range
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2%
|
21 – 50th
|
±6%
|
51 – 99th
|
±10%
|
Harmonics of AC Current in Magnitude
(1 to 99th order, min. current at the 50 or 60 Hz, True RMS < 300A)
Range (0 – 300A)
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2% of reading ± 4A
|
21 – 50th
|
±4% of reading ± 4A
|
51 – 99th
|
±6% of reading ± 4A
|
(1 to 99th order, min. current at the 50 or 60 Hz, 3000A > True RMS > 300A)
Range (300–3000A)
|
Resolution
|
Accuracy
|
1 – 20th
|
0.1%
|
±2% of reading ± 40A
|
21 – 50th
|
±4% of reading ± 40A
|
51 – 99th
|
±6% of reading ± 40A
|
Power Factor (PF)
Range
|
Resolution
|
Accuracy
|
> 20V and > 30A
|
< 20V or < 30A
|
0.000 – 1.000
|
0.001
|
± 0.04
|
±0.1
|
Phase Angle (Φ, V > 20V, A > 30A)
Range
|
Resolution
|
Accuracy
|
-180° to 180°
|
0.1°
|
± 2°
|
0° to 360°
|
Frequency of ACV (RMS value > 10V) or ACA (RMS value > 30A)
Range
|
Resolution
|
Accuracy
|
45 – 65 Hz
|
0.1 Hz
|
± 0.2Hz
|
Total Harmonic Distortion (THD-F)
Range
|
Resolution
|
Accuracy
|
0.0 – 20%
|
0.1%
|
± 2%
|
20 – 100%
|
± 6% of reading ± 5%
|
100 – 999.9 %
|
± 10% of reading ± 10%
|
General Specifications: Indoors Use
PROVA 6830A Analyzer
Battery Type:
|
1.5V SUM-3 x 8
|
External DC Input:
|
Use only power supply adapter Model PHAPSA
|
Display:
|
Dot Matrix LCD (240x128) with backlight
|
LCD Update Rate:
|
1 time / second
|
Power Consumption:
|
140mA (approx.)
|
No. Of Samples:
|
1024 samples / period
|
Data Logging Files:
|
85
|
Max. File Capacity:
|
17474 records (3P4W, 3P3W)
26210 records (1P3W)
52420 records (1P2W)
4096 records (50 Harmonics / record)
|
Sampling Time:
|
2 to 3000 seconds for data logging
|
Low battery Indication:
|
|
Overload Indication:
|
OL
|
Operating Temperature:
|
-10°C to 50°C
|
Operating Humidity:
|
less than 85% relative
|
Storage Temperature:
|
-20°C to 60°C
|
Storage Humidity:
|
less than 75% relative
|
Dimension:
|
257 (L) x 155 (W) x 57 (H) mm
10.1” (L) x 6.1” (W) x 2.3” (H)
|
Weight:
|
1160g (Batteries included)
|
Accessories:
|
Probes (model 3007) x 3
Test leads (3 meter long) x 4
Alligator clips x 4, Carrying bag x 1
Users manual x 1, Batteries 1.5V x 8
AC power adapter x 1, Software CD x 1 Software users manual x 1 USB to RS232 cable x 1
|
AFLEX 3007 Flexible Current Probes
Probe Length: ( 3007-24)
|
24 in / 610 mm
|
Minimum Bending Diameter:
|
35mm
|
Connector Diameter:
|
23mm
|
Cable Diameter:
|
14mm
|
Cable Length from Probe to Box:
|
1700mm
|
Cable Length from Box to Output:
|
1700mm
|
Range Selection:
|
Manual (300A, 3000A)
|
Battery:
|
powered by power analyzer
|
Dimension (Box):
|
130mm(L) x 80mm(W)x 43mm(H)
5.1”(L) x 3.1”(W) x 1.7”(H)
|
Weight:
|
410g
|