TES-3014

Digital Clamp Meter

Availability: In stock
  • Capacitance measurement 2000µF.
  • Variable-frequency drive VFD voltage & Current measurement.
  • ACA: 600A (3013), 1000A (3014).
  • Peak / Data Hold.
  • Frequency Count / Diode Check.
  • Continuity Buzzer.
    • Shipping
    • Payments
    • Quantity
    • US$ 60Log in for sale price
    To show price, please join membership and log in.
    Digital Clamp Meter
    Digital Clamp Meter
    • Specification
    • Application

     

    ELECTRICAL SPECIFICATION:

      AC Current

    Range

    Resolution

    Accuracy (50Hz/60Hz)

    Overload Protection

    20A

    10mA

    ±(2%rdg + 5dgts)

    1000A

    (Within 30 seconds)

    200A

    100mA

    600A. 1000A

    1A

     

    DC Voltage 

    Range

    Resolution

    Accuracy

    Input Impedance

    Overload Protection

    600V

    1V

    ±(0.8%rdg + 2dgt)

    10MΩ

    600V

     

    AC Voltage 

    Range

    Resolution

    Accuracy

    Input Impedance

    Overload Protection

    600V

    1V

    ±(1.2%rdg + 3dgts) at 50, 60Hz

    ±(5%rdg + 3dgts) at 40 ~ 400Hz

    10MΩ

    600V

     

    Resistance (Ω) 

    Range

    Resolution

    Accuracy

    Max. Open Circuit Voltage

    Overload Protection

    200Ω

    100mΩ

    ±(1%rdg + 2dgts)

    3.5V

    600V

    20kΩ

    10Ω

    0.3V

     

    Frequency (Hz) (10Hz-2KHz) 

    Range

    Resolution

    Accuracy

    Max. Input Sensitivity

    Max. Allowable Applied Voltage

    2kHz

    1Hz

    ±(1%rdg + 2dgts)

    100mVrms

    600V

     

    Diode ()

    Range

    Resolution

    Max. Test Current

    Max. Open Circuit Voltage

    Over Voltage Protection

    1mV

    1.5mA

    3.5V

    600V

     

    Continuity (BEEPER)

    Range

    Resolution

    Operation Resistance

    Max. Open Circuit Voltage

    Over Protection

             

    0.1Ω

    Below 100Ω

    3.5V

    600V

     

    Capacitance (µF)

    Range

    Resolution

    Accuracy

    Max. Open Circuit Voltage

    Over Protection

    2000µF

    1µF

    ±(5%rdg + 2dgts)

    3.5V

    600V

     

    Peak Hold Measurement (23±5Below 80% RH) 

    AC Current

    Range

    Resolution

    Accuracy (50Hz 60Hz)

    Overload Protection

    20A

    10mA

    ±(2%rdg + 10dgts)

    1000A

    (Within 30 seconds)

    200A

    100mA

    600A, 1000A

    1A

     

    AC Voltage

    Range

    Resolution

    Accuracy (50Hz 60Hz)

    Input Impedance

    Overload Protection

    600V

    1V

    ±(1.5%rdg + 8dgts)

    10MΩ

    600V

     

     GENERAL SPECIFICATION:
    *  Operating Temperature: 0~40, 0-80% RH. 
    *  Sampling Rate: 2.5 times per second. 
    *  The time of peak Value Response: about 100ms. 
    *  Power Source: 006P DC 9V 1pc. 
    *  Size & Weight: 208mm×65mm×31mm & 310g.
    * Accessories: Test probe 1 pair, Instruction Manual,Carrying Case, Battery.

    Related Products