Product Categories
  • Accessories (8)

  • Anemometer (11)

  • Battery Impedance Tester (2)

  • Clamp Meter (21)

  • CO/ CO2 Tester (3)

  • Calibrator (5)

  • EMF Tester (7)

  • Earth Ground Tester (4)

  • Flexible Clamp Meter (7)

  • Harmonic Clamp Meter (11)

  • Humidity Temperature Meter (8)

  • Infrared Thermometer (4)

  • Insulation tester (4)

  • Light Meter (13)

  • Lan Cable Tester (2)

  • Multimeter (8)

  • Milli / Micro Ohm Meter (2)

  • Power Clamp Meter (7)

  • Power Supply (1)

  • PH Meter (4)

  • Particle Counter (2)

  • Solar Power Meter (7)

  • Sound Level Meter (16)

  • Tachometer (2)

  • Thermometer (18)

  • VIBRATION METER (3)

TES
PROVA
Products
Power & Harmonics Tester

Power & Harmonics Tester

PROVA-6605
  • Active (W, KW, HP), reactive (VAR, KVAR) and apparent (VA, KVA) power.
  • Power factor (PF), phase angle (Φ), and energy (WH, KWH).
  • Non-interrupted AC current harmonic analysis.
  • 1 to 99th order of harmonics at 2.0% basic accuracy.
  • Total harmonic distortion (%THD-F) and crest factor (CF).
  • True RMS measurement of V at 0.5% basic accuracy.
  • True RMS measurement of A at 2.0% basic accuracy.
  • Fast peak function (39μs for 50 Hz, 33μs for 60Hz).
  • Resistance and Continuity with Beeper.
  • Measurement of balanced 3Φ power.
  • Measurement of balanced 3Φ sequence.
  • Programmable CT ratio from 1 to 250.
  • Max, Min and data hold functions.
  • Active power in H.P..
  • Auto power off function in 30 minutes.
  • AC current: 10~1500A.
    • Add To Cart
    • View Detail
    US$ 594
    Log in for sale price
    Power and Harmonics Analyzer - Model 3006 (6000A)

    Power and Harmonics Analyzer - Model 3006 (6000A)

    PROVA 6830A-5
  • Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W.
  • True RMS value (V123 and I123).
  • Active Power (W, KW, MW, GW).
  • Apparent and Reactive Power (KVA, KVAR).
  • Power Factor (PF), Phase Angle (Φ).
  • Energy (WH, KWH, KVARH, PFH).
  • AC Current (see below) and Voltage measurement: True RMS, Auto Range.
     1. 6830A+6801: 0.04A to 100A
     2. 6830A+6802: 0.4A to 1000A
     3. 6830A+3007: 10A to 3000A
     4. 6830A+3009: 6A to 1200A
     5. 6830A+3006: 20A to 6000A
  • Capable of analyzing IT standby power consumption to the maximum demand of a factory.
  • Display of 35 Parameters in One Screen (3P4W).
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios.
  • Display of Overlapped Voltage and Current Waveform.
  • Average Demand (AD in W, KW, MW).
  • Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period.
  • Harmonic Analysis to the 99th Order.
  • Display of 50 Harmonics in one Screen with Waveform.
  • Display of Waveform with Peak Values (1024 Samples / Period).
  • Analysis of Total Harmonic Distortion (THD-F).
  • Graphic Phasor Diagram with 3 Phase System Parameters.
  • Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%).
  • DIP, SWELL, and OUTAGE are included in transient events.
  • 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR).
  • 3 Phase Voltage or Current Unbalance Factor (d0%, d2%).
  • Calculated Unbalanced Current through Neutral Line (In).
  • 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system).
  • Output of Waveform, Power Parameters and Harmonics at Command.
  • Large Dot Matrix LCD Display with Backlight.
  • Software to work with PC via Optical Isolated RS-232C to USB Interface.
  • Built-in timer and calendar for data logging.
     
     Conductor Size:
     ■ Model 6801(100A) 30mm(approx)
      210mm(L)*62mm(W)*36mm(H),200g(Weight)
     ■ Model 6802(1000A) 55mm(approx),64*24mm(bus bar)
      244mm(L)*97mm(W)*46mm(H),600g(Weight)
     ■ Model 3007 (3000A) 24in/610mm(Probe Length)
      130mm(L)*80mm(W)*43mm(H),410g(Weight)
     ■ Model 3009 (1200A) 18in/460mm(Probe Length)
      130mm(L)*80mm(W)*43mm(H),390g(Weight)
     ■ Model 3006(6000A)
      130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
    • Add To Cart
    • View Detail
    US$ 2475
    Log in for sale price
    Power and Harmonics Analyzer - Model 3009 (1200A)

    Power and Harmonics Analyzer - Model 3009 (1200A)

    PROVA 6830A-4
  • Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W.
  • True RMS value (V123 and I123).
  • Active Power (W, KW, MW, GW).
  • Apparent and Reactive Power (KVA, KVAR).
  • Power Factor (PF), Phase Angle (Φ).
  • Energy (WH, KWH, KVARH, PFH).
  • AC Current (see below) and Voltage measurement: True RMS, Auto Range.
     1. 6830A+6801: 0.04A to 100A
     2. 6830A+6802: 0.4A to 1000A
     3. 6830A+3007: 10A to 3000A
     4. 6830A+3009: 6A to 1200A
     5. 6830A+3006: 20A to 6000A
  • Capable of analyzing IT standby power consumption to the maximum demand of a factory.
  • Display of 35 Parameters in One Screen (3P4W).
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios.
  • Display of Overlapped Voltage and Current Waveform.
  • Average Demand (AD in W, KW, MW).
  • Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period.
  • Harmonic Analysis to the 99th Order.
  • Display of 50 Harmonics in one Screen with Waveform.
  • Display of Waveform with Peak Values (1024 Samples / Period).
  • Analysis of Total Harmonic Distortion (THD-F).
  • Graphic Phasor Diagram with 3 Phase System Parameters.
  • Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%).
  • DIP, SWELL, and OUTAGE are included in transient events.
  • 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR).
  • 3 Phase Voltage or Current Unbalance Factor (d0%, d2%).
  • Calculated Unbalanced Current through Neutral Line (In).
  • 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system).
  • Output of Waveform, Power Parameters and Harmonics at Command.
  • Large Dot Matrix LCD Display with Backlight.
  • Software to work with PC via Optical Isolated RS-232C to USB Interface.
  • Built-in timer and calendar for data logging.
     
     Conductor Size:
     ■ Model 6801(100A) 30mm(approx)
      210mm(L)*62mm(W)*36mm(H),200g(Weight)
     ■ Model 6802(1000A) 55mm(approx),64*24mm(bus bar)
      244mm(L)*97mm(W)*46mm(H),600g(Weight)
     ■ Model 3007 (3000A) 24in/610mm(Probe Length)
      130mm(L)*80mm(W)*43mm(H),410g(Weight)
     ■ Model 3009 (1200A) 18in/460mm(Probe Length)
      130mm(L)*80mm(W)*43mm(H),390g(Weight)
     ■ Model 3006(6000A)
      130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
    • Add To Cart
    • View Detail
    US$ 2475
    Log in for sale price
    Power and Harmonics Analyzer - Model 3007 (3000A)

    Power and Harmonics Analyzer - Model 3007 (3000A)

    PROVA 6830A-3
  • Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W.
  • True RMS value (V123 and I123).
  • Active Power (W, KW, MW, GW).
  • Apparent and Reactive Power (KVA, KVAR).
  • Power Factor (PF), Phase Angle (Φ).
  • Energy (WH, KWH, KVARH, PFH).
  • AC Current (see below) and Voltage measurement: True RMS, Auto Range.
     1. 6830A+6801: 0.04A to 100A
     2. 6830A+6802: 0.4A to 1000A
     3. 6830A+3007: 10A to 3000A
     4. 6830A+3009: 6A to 1200A
     5. 6830A+3006: 20A to 6000A
  • Capable of analyzing IT standby power consumption to the maximum demand of a factory.
  • Display of 35 Parameters in One Screen (3P4W).
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios.
  • Display of Overlapped Voltage and Current Waveform.
  • Average Demand (AD in W, KW, MW).
  • Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period.
  • Harmonic Analysis to the 99th Order.
  • Display of 50 Harmonics in one Screen with Waveform.
  • Display of Waveform with Peak Values (1024 Samples / Period).
  • Analysis of Total Harmonic Distortion (THD-F).
  • Graphic Phasor Diagram with 3 Phase System Parameters.
  • Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%).
  • DIP, SWELL, and OUTAGE are included in transient events.
  • 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR).
  • 3 Phase Voltage or Current Unbalance Factor (d0%, d2%).
  • Calculated Unbalanced Current through Neutral Line (In).
  • 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system).
  • Output of Waveform, Power Parameters and Harmonics at Command.
  • Large Dot Matrix LCD Display with Backlight.
  • Software to work with PC via Optical Isolated RS-232C to USB Interface.
  • Built-in timer and calendar for data logging.
     
     Conductor Size:
     ■ Model 6801(100A) 30mm(approx)
      210mm(L)*62mm(W)*36mm(H),200g(Weight)
     ■ Model 6802(1000A) 55mm(approx),64*24mm(bus bar)
      244mm(L)*97mm(W)*46mm(H),600g(Weight)
     ■ Model 3007 (3000A) 24in/610mm(Probe Length)
      130mm(L)*80mm(W)*43mm(H),410g(Weight)
     ■ Model 3009 (1200A) 18in/460mm(Probe Length)
      130mm(L)*80mm(W)*43mm(H),390g(Weight)
     ■ Model 3006(6000A)
      130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
    • Add To Cart
    • View Detail
    US$ 2475
    Log in for sale price
    Power and Harmonics Analyzer - Model 6802(1000A)

    Power and Harmonics Analyzer - Model 6802(1000A)

    PROVA 6830A-2
  • Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W.
  • True RMS value (V123 and I123).
  • Active Power (W, KW, MW, GW).
  • Apparent and Reactive Power (KVA, KVAR).
  • Power Factor (PF), Phase Angle (Φ).
  • Energy (WH, KWH, KVARH, PFH).
  • AC Current (see below) and Voltage measurement: True RMS, Auto Range.
     1. 6830A+6801: 0.04A to 100A
     2. 6830A+6802: 0.4A to 1000A
     3. 6830A+3007: 10A to 3000A
     4. 6830A+3009: 6A to 1200A
     5. 6830A+3006: 20A to 6000A
  • Capable of analyzing IT standby power consumption to the maximum demand of a factory.
  • Display of 35 Parameters in One Screen (3P4W).
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios.
  • Display of Overlapped Voltage and Current Waveform.
  • Average Demand (AD in W, KW, MW).
  • Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period.
  • Harmonic Analysis to the 99th Order.
  • Display of 50 Harmonics in one Screen with Waveform.
  • Display of Waveform with Peak Values (1024 Samples / Period).
  • Analysis of Total Harmonic Distortion (THD-F).
  • Graphic Phasor Diagram with 3 Phase System Parameters.
  • Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%).
  • DIP, SWELL, and OUTAGE are included in transient events.
  • 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR).
  • 3 Phase Voltage or Current Unbalance Factor (d0%, d2%).
  • Calculated Unbalanced Current through Neutral Line (In).
  • 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system).
  • Output of Waveform, Power Parameters and Harmonics at Command.
  • Large Dot Matrix LCD Display with Backlight.
  • Software to work with PC via Optical Isolated RS-232C to USB Interface.
  • Built-in timer and calendar for data logging.
     
     Conductor Size:
     ■ Model 6801(100A) 30mm(approx)
      210mm(L)*62mm(W)*36mm(H),200g(Weight)
     ■ Model 6802(1000A) 55mm(approx),64*24mm(bus bar)
      244mm(L)*97mm(W)*46mm(H),600g(Weight)
     ■ Model 3007 (3000A) 24in/610mm(Probe Length)
      130mm(L)*80mm(W)*43mm(H),410g(Weight)
     ■ Model 3009 (1200A) 18in/460mm(Probe Length)
      130mm(L)*80mm(W)*43mm(H),390g(Weight)
     ■ Model 3006(6000A)
      130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
    • Add To Cart
    • View Detail
    US$ 2475
    Log in for sale price
    Power and Harmonics Analyzer - Model 6801(100A)

    Power and Harmonics Analyzer - Model 6801(100A)

    PROVA 6830A-1
  • Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W.
  • True RMS value (V123 and I123).
  • Active Power (W, KW, MW, GW).
  • Apparent and Reactive Power (KVA, KVAR).
  • Power Factor (PF), Phase Angle (Φ).
  • Energy (WH, KWH, KVARH, PFH).
  • AC Current (see below) and Voltage measurement: True RMS, Auto Range.
     1. 6830A+6801: 0.04A to 100A
     2. 6830A+6802: 0.4A to 1000A
     3. 6830A+3007: 10A to 3000A
     4. 6830A+3009: 6A to 1200A
     5. 6830A+3006: 20A to 6000A
  • Capable of analyzing IT standby power consumption to the maximum demand of a factory.
  • Display of 35 Parameters in One Screen (3P4W).
  • Programmable CT (1 to 600) and PT (1 to 3000) Ratios.
  • Display of Overlapped Voltage and Current Waveform.
  • Average Demand (AD in W, KW, MW).
  • Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period.
  • Harmonic Analysis to the 99th Order.
  • Display of 50 Harmonics in one Screen with Waveform.
  • Display of Waveform with Peak Values (1024 Samples / Period).
  • Analysis of Total Harmonic Distortion (THD-F).
  • Graphic Phasor Diagram with 3 Phase System Parameters.
  • Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%).
  • DIP, SWELL, and OUTAGE are included in transient events.
  • 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR).
  • 3 Phase Voltage or Current Unbalance Factor (d0%, d2%).
  • Calculated Unbalanced Current through Neutral Line (In).
  • 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system).
  • Output of Waveform, Power Parameters and Harmonics at Command.
  • Large Dot Matrix LCD Display with Backlight.
  • Software to work with PC via Optical Isolated RS-232C to USB Interface.
  • Built-in timer and calendar for data logging.
     
     Conductor Size:
     ■ Model 6801(100A) 30mm(approx)
      210mm(L)*62mm(W)*36mm(H),200g(Weight)
     ■ Model 6802(1000A) 55mm(approx),64*24mm(bus bar)
      244mm(L)*97mm(W)*46mm(H),600g(Weight)
     ■ Model 3007 (3000A) 24in/610mm(Probe Length)
      130mm(L)*80mm(W)*43mm(H),410g(Weight)
     ■ Model 3009 (1200A) 18in/460mm(Probe Length)
      130mm(L)*80mm(W)*43mm(H),390g(Weight)
     ■ Model 3006(6000A)
      130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
    • Add To Cart
    • View Detail
    US$ 2475
    Log in for sale price
    Power Harmonics and Leakage Tester

    Power Harmonics and Leakage Tester

    PROVA-23
  • MODEL PROVA 19, 21, 23
  • True RMS value (V and A).
  • Leakage Current Measurement at 10 μ A Resolution.
  • Harmonic Analysis (V and A) to the 99 th Order.
  • Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz).
  • Non-interrupted Harmonic Analysis.
  • Analysis of Total Harmonic Distortion (THD-F).
  • Analysis of Crest Factor (C.F.).
  • Fast Peak Function (33 μ s and 39 μ s).
  • Programmable CT Ratio (1 to 250).

    Model 21(50A) and 23(100A)
  • W, KW, H.P.
  • VA, KVA, VAR, KVAR.
  • PF, Phase Angle ( Φ ).
  • Energy (mWH, WH, KWH).
  • Analysis of Standby Power Consumption.
  • Balanced 3 Φ Power Quality.
  • Balanced 3 Φ Sequence.
    • Add To Cart
    • View Detail
    US$ 430
    Log in for sale price
    Power Harmonics and Leakage Tester

    Power Harmonics and Leakage Tester

    PROVA-21
  • MODEL PROVA 19, 21, 23
  • True RMS value (V and A).
  • Leakage Current Measurement at 10 μ A Resolution.
  • Harmonic Analysis (V and A) to the 99 th Order.
  • Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz).
  • Non-interrupted Harmonic Analysis.
  • Analysis of Total Harmonic Distortion (THD-F).
  • Analysis of Crest Factor (C.F.).
  • Fast Peak Function (33 μ s and 39 μ s).
  • Programmable CT Ratio (1 to 250).

    Model 21(50A) and 23(100A)
  • W, KW, H.P.
  • VA, KVA, VAR, KVAR.
  • PF, Phase Angle ( Φ ).
  • Energy (mWH, WH, KWH).
  • Analysis of Standby Power Consumption.
  • Balanced 3 Φ Power Quality.
  • Balanced 3 Φ Sequence.
    • Add To Cart
    • View Detail
    US$ 396
    Log in for sale price
    Power Harmonics and Leakage Tester

    Power Harmonics and Leakage Tester

    PROVA 19
  • MODEL PROVA 19, 21, 23
  • True RMS value (V and A).
  • Leakage Current Measurement at 10 μ A Resolution.
  • Harmonic Analysis (V and A) to the 99 th Order.
  • Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz).
  • Non-interrupted Harmonic Analysis.
  • Analysis of Total Harmonic Distortion (THD-F).
  • Analysis of Crest Factor (C.F.).
  • Fast Peak Function (33 μ s and 39 μ s).
  • Programmable CT Ratio (1 to 250).

    Model 21(50A) and 23(100A)
  • W, KW, H.P.
  • VA, KVA, VAR, KVAR.
  • PF, Phase Angle ( Φ ).
  • Energy (mWH, WH, KWH).
  • Analysis of Standby Power Consumption.
  • Balanced 3 Φ Power Quality.
  • Balanced 3 Φ Sequence.
    • Add To Cart
    • View Detail
    US$ 363
    Log in for sale price
    Graphic Power Quality Analyzer

    Graphic Power Quality Analyzer

    PROVA-6200
  • Analysis for Single Phase and Balanced 3 phase system.
  • True RMS Value (V and I).
  • Active Power (K,KW,MW,GW).
  • Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR).
  • Power Factor (PF), Phase Angle( Φ ).
  • Energy (WH,KWH,KVARH,PFH).
  • Programmable PT(1 to 3000)Ratios.
  • Display of Overlapped Voltage and Current Waveform.
  • Maximum Demand (MD in W,KW,MW) with programmable Period.
  • Harmonic Analysis (V and I) to 50th Order.
  • Display of 25 Harmonics in one screen.
  • Optical Isolated RS-232C Interface.
  • Smart Datalogging to save Battery.
  • Datalogging of 32,64,128 or 256 points/cycles.
  • Analysis of Total Harmonic Distortion (%THD-F).
  • Graphic Phasor Diagram.
  • Capture 128 Transient Events (Time+Cycles+Faults) with Programmable Threshold(%),also can be reviewed in LCD.
  • 50000 Records with Programmable Interval (1 to 6000 seconds).
  • Real-time Output of Waveform, Power Parameters and Harmonics at Command.
  • Large Dot Matrix LCD Display with Backlight.
  • Power for Long-term Monitoring.
  • Built -in Calendar Clock for Data Logging.
    • Add To Cart
    • View Detail
    US$ 980
    Log in for sale price
    • ‹
    • 1
    • 2
    • ›
    • Products
    • News
    • Application
    • FAQ
    • About us
    • Contact us
    • Sitemap
    • Information
      • Shopping Procedure
      • Shipping Fee
      • Payment Method
      • Return/Replacement Policies
      • Repairs & Warranty
      • Privacy Policy
    • Vip
      • Order history
      • Account Details
      • Wish list
      • Member FAQ
      • Shopping Cart
      • Membership
    • Contact Us
      • 7F.-1, No. 102, Zhouzi St, Neihu Dist, Taipei City 114, Taiwan
      • TEL: +886-2-2657-9360
      • FAX: +886-2-2657-9366
      • instservice@instaligo.com.tw
      • Monday-Frigay 8:30 AM~5:30 PM
    Copyright © 2016 Instaligo Inc. All rights reserved