•Five kinds of Dual display:
Hold + Average
Max + Min
ΔMax + ΔMin
Peak Max + Peak Min
Δ Peak Max + Δ Peak Min
•With backlight.
•Auto Range: V, A, Resistance, Capacitance and Temperature.
•Auto-Power-off function (30 min).
•Ideal for works in crowded switch box or cable areas.
Search
DC/AC Clamp Meter
PROVA A1
•Five kinds of Dual display:
Hold + Average
Max + Min
ΔMax + ΔMin
Peak Max + Peak Min
Δ Peak Max + Δ Peak Min
•With backlight.
•Auto Range: V, A, Resistance, Capacitance and Temperature.
•Auto-Power-off function (30 min).
•Ideal for works in crowded switch box or cable areas.
Hold + Average
Max + Min
ΔMax + ΔMin
Peak Max + Peak Min
Δ Peak Max + Δ Peak Min
•With backlight.
•Auto Range: V, A, Resistance, Capacitance and Temperature.
•Auto-Power-off function (30 min).
•Ideal for works in crowded switch box or cable areas.
- US$ 265
- Log in for sale price
Clamp Meter
PROVA-2003
‧DC/AC 2000A.
‧Cable f 55mm Bus Bar 72mm(D) x 22mm(W).
‧True RMS (2000).
‧Average Sensing (2003).
‧DCA One Touch Zero.
‧Auto Range A, V, W.
‧Continuity.
‧Max/Min/Hold.
‧Relative Measurement.
‧Cable f 55mm Bus Bar 72mm(D) x 22mm(W).
‧True RMS (2000).
‧Average Sensing (2003).
‧DCA One Touch Zero.
‧Auto Range A, V, W.
‧Continuity.
‧Max/Min/Hold.
‧Relative Measurement.
- US$ 231
- Log in for sale price
Trms Clamp Meter (DC/AC 1000A)
TES-3910
•Capacitance measurement 1000µF.
•Variable-frequency drive (VFD) V & Hz measurement.
•Lo-Z voltage measurement to drain ghost voltages.
•Check 3Φ phase sequence.
•True RMS reading on AC and DC+AC mode.
•Inrush current measurement.
•A measurement for HVAC flame sensors.
•mV measurement range to interface with other accessories.
•Crest Factor & Harmonic ratio measurement.
•Data hold, Auto hold & Peak hold mode.
•Max/Min/Avg record mode.
•Data memory & read function.
•Variable-frequency drive (VFD) V & Hz measurement.
•Lo-Z voltage measurement to drain ghost voltages.
•Check 3Φ phase sequence.
•True RMS reading on AC and DC+AC mode.
•Inrush current measurement.
•A measurement for HVAC flame sensors.
•mV measurement range to interface with other accessories.
•Crest Factor & Harmonic ratio measurement.
•Data hold, Auto hold & Peak hold mode.
•Max/Min/Avg record mode.
•Data memory & read function.
- US$ 127
- Log in for sale price
Battery Capacity Tester
TES-32A
‧Test Condition Without Shutting Down Battery.
‧Simultaneously Measure Battery Resistance, Voltage.
‧Comparator Function.
‧Rates Conditions as Pass, Warning, or Fail.
‧Memory and Read Function.
‧Compact and Lightweight.
‧USB PC Interface.
‧Simultaneously Measure Battery Resistance, Voltage.
‧Comparator Function.
‧Rates Conditions as Pass, Warning, or Fail.
‧Memory and Read Function.
‧Compact and Lightweight.
‧USB PC Interface.
- US$ 429
- Log in for sale price
Clamp Meter
PROVA-2000
‧DC/AC 2000A.
‧Cable f 55mm, Bus Bar 72mm(D) x 22mm(W).
‧True RMS (2000).
‧Average Sensing (2003).
‧DCA One Touch Zero.
‧Auto Range A, V, W.
‧Continuity.
‧Max/Min/Hold.
‧Relative Measurement.
‧Cable f 55mm, Bus Bar 72mm(D) x 22mm(W).
‧True RMS (2000).
‧Average Sensing (2003).
‧DCA One Touch Zero.
‧Auto Range A, V, W.
‧Continuity.
‧Max/Min/Hold.
‧Relative Measurement.
- US$ 280
- Log in for sale price
AC/DC mA Current Probe
PROVA-15
‧Accurate DC/AC current probe for current measurement.
‧1mDCA high resolution on 4A DC range.
‧0.1mACA high resolution on 400mA AC range.
‧One touch zero for DCA adjustment.
‧23 mm diameter jaw.
‧Connect to an oscilloscope to observe current waveform.
‧Connect to a chart recorder/ datalogger/ DMM to record current data.
‧1mDCA high resolution on 4A DC range.
‧0.1mACA high resolution on 400mA AC range.
‧One touch zero for DCA adjustment.
‧23 mm diameter jaw.
‧Connect to an oscilloscope to observe current waveform.
‧Connect to a chart recorder/ datalogger/ DMM to record current data.
- US$ 220
- Log in for sale price
AC/DC mA True RMS Clamp Meter
PROVA-11
‧ Accurate digital clamp meter for Current measurement:
AC current: 0 ~ 30A (True RMS).
DC current: 0 ~ 40A.
‧ Accurate digital clamp meter for Voltage measurement:
AC voltage: 0 ~ 400V (True RMS).
DC voltage: 0 ~ 400V.
‧ AC 0.1mA, DC 1mA high resolution.
‧ One touch zero for DCA adjustment.
‧ 23 mm diameter jaw.
‧ Large 3 3/4 digits LCD.
‧ Fast bargraph display (30 times/sec.) for transient observation.
‧ Max/Min and Data Hold functions.
‧ Auto power off.
‧ Easy single rotary switch for any function selection.
AC current: 0 ~ 30A (True RMS).
DC current: 0 ~ 40A.
‧ Accurate digital clamp meter for Voltage measurement:
AC voltage: 0 ~ 400V (True RMS).
DC voltage: 0 ~ 400V.
‧ AC 0.1mA, DC 1mA high resolution.
‧ One touch zero for DCA adjustment.
‧ 23 mm diameter jaw.
‧ Large 3 3/4 digits LCD.
‧ Fast bargraph display (30 times/sec.) for transient observation.
‧ Max/Min and Data Hold functions.
‧ Auto power off.
‧ Easy single rotary switch for any function selection.
- US$ 280
- Log in for sale price
DC/AC Current Probe
CM-05
‧Accurate and High Resolution.
‧23 mm Conductor Diameter.
‧One Touch Zero.
‧23 mm Conductor Diameter.
‧One Touch Zero.
- US$ 99
- Log in for sale price
Clamp Meter/Automotive Clamp
CM-02
‧10 mA high resolution on 40A DC/AC range.
‧Temperature (℃ or ℉) and Capacitance.
‧One touch zero for DCA adjustment.
‧Auto-range for V, A, Ω, F, and temperature.
‧23 mm diameter jaw.
‧Auto-power-off (15 minutes).
‧Fast bargraph display (30 times/sec.) for transient observation.
‧Continuity and frequency measurements.
‧Max/Min and Data Hold functions.
‧600V overload protection for ohm measurement.
‧Ideal for works in crowded switch box or cable areas.
‧Temperature (℃ or ℉) and Capacitance.
‧One touch zero for DCA adjustment.
‧Auto-range for V, A, Ω, F, and temperature.
‧23 mm diameter jaw.
‧Auto-power-off (15 minutes).
‧Fast bargraph display (30 times/sec.) for transient observation.
‧Continuity and frequency measurements.
‧Max/Min and Data Hold functions.
‧600V overload protection for ohm measurement.
‧Ideal for works in crowded switch box or cable areas.
- US$ 215
- Log in for sale price