‧AC current measurement up to 3000A (True RMS): basic accuracy 1% of range.
‧AC voltage measurement up to 600V (True RMS): basic accuracy 0.5% of range.
‧AC watt measurement up to 9999KW: basic accuracy 1% of range.
‧Power quality analysis for single and balanced 3 phase system.
‧Measurement of balanced 3Φ power quality and phase sequence.
‧Active (W, KW, HP), Reactive (VAR, KVAR) and Apparent (VA, KVA) power.
‧Power factor (PF), Phase angle (Φ), and Energy (WH, KWH).
‧1 to 50th order of harmonics at 2.0% basic accuracy.
‧Total harmonic distortion (%THD-F) and Crest factor (CF).
‧Frequency of ACV or ACA: 45 ~ 65 Hz.
‧Fast peak function (39μs for 50 Hz, 33μs for 60Hz).
‧Work with PC via USB interface.
‧Programmable CT ratio from 1 to 250.
‧Max / Min / Data Hold functions.
‧Auto power off function in 30 minutes.
‧Data logging memory size: 8000 records.
Search
Flexible AC Current Clamp
AFLEX-3002
‧AC current up to 3000A (True RMS).
‧AC voltage up to 600V (True RMS).
‧Frequency of ACA or ACV: 45~65Hz.
‧Direct reading, no DMM required.
‧AC current (TRMS) measurement at with 1% of scale basic accuracy.
‧AC voltage (TRMS) measurement at with 0.5% basic accuracy.
‧Fast peak function (39μs for 50 Hz, 33μs for 60Hz).
‧Max, Min and Data Hold functions.
‧Auto power off - 15 minutes.
‧Range selection: auto.
‧Low battery indication.
‧AC voltage up to 600V (True RMS).
‧Frequency of ACA or ACV: 45~65Hz.
‧Direct reading, no DMM required.
‧AC current (TRMS) measurement at with 1% of scale basic accuracy.
‧AC voltage (TRMS) measurement at with 0.5% basic accuracy.
‧Fast peak function (39μs for 50 Hz, 33μs for 60Hz).
‧Max, Min and Data Hold functions.
‧Auto power off - 15 minutes.
‧Range selection: auto.
‧Low battery indication.
- US$ 325
- Log in for sale price
Power Harmonics and Leakage Tester
PROVA-23
MODEL PROVA 19, 21, 23
‧ True RMS value (V and A).
‧ Leakage Current Measurement at 10 μ A Resolution.
‧ Harmonic Analysis (V and A) to the 99 th Order.
‧ Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz).
‧ Non-interrupted Harmonic Analysis.
‧ Analysis of Total Harmonic Distortion (THD-F).
‧ Analysis of Crest Factor (C.F.).
‧Fast Peak Function (33 μ s and 39 μ s).
‧ Programmable CT Ratio (1 to 250).
Model 21(50A) and 23(100A)
‧ W, KW, H.P.
‧ VA, KVA, VAR, KVAR.
‧ PF, Phase Angle ( Φ ).
‧Energy (mWH, WH, KWH).
‧ Analysis of Standby Power Consumption.
‧Balanced 3 Φ Power Quality.
‧Balanced 3 Φ Sequence.
‧ True RMS value (V and A).
‧ Leakage Current Measurement at 10 μ A Resolution.
‧ Harmonic Analysis (V and A) to the 99 th Order.
‧ Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz).
‧ Non-interrupted Harmonic Analysis.
‧ Analysis of Total Harmonic Distortion (THD-F).
‧ Analysis of Crest Factor (C.F.).
‧Fast Peak Function (33 μ s and 39 μ s).
‧ Programmable CT Ratio (1 to 250).
Model 21(50A) and 23(100A)
‧ W, KW, H.P.
‧ VA, KVA, VAR, KVAR.
‧ PF, Phase Angle ( Φ ).
‧Energy (mWH, WH, KWH).
‧ Analysis of Standby Power Consumption.
‧Balanced 3 Φ Power Quality.
‧Balanced 3 Φ Sequence.
- US$ 430
- Log in for sale price
Power Harmonics and Leakage Tester
PROVA-21
MODEL PROVA 19, 21, 23
‧ True RMS value (V and A).
‧ Leakage Current Measurement at 10 μ A Resolution.
‧ Harmonic Analysis (V and A) to the 99 th Order.
‧ Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz).
‧ Non-interrupted Harmonic Analysis.
‧ Analysis of Total Harmonic Distortion (THD-F).
‧ Analysis of Crest Factor (C.F.).
‧Fast Peak Function (33 μ s and 39 μ s).
‧ Programmable CT Ratio (1 to 250).
Model 21(50A) and 23(100A)
‧ W, KW, H.P.
‧ VA, KVA, VAR, KVAR.
‧ PF, Phase Angle ( Φ ).
‧Energy (mWH, WH, KWH).
‧ Analysis of Standby Power Consumption.
‧Balanced 3 Φ Power Quality.
‧Balanced 3 Φ Sequence.
‧ True RMS value (V and A).
‧ Leakage Current Measurement at 10 μ A Resolution.
‧ Harmonic Analysis (V and A) to the 99 th Order.
‧ Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz).
‧ Non-interrupted Harmonic Analysis.
‧ Analysis of Total Harmonic Distortion (THD-F).
‧ Analysis of Crest Factor (C.F.).
‧Fast Peak Function (33 μ s and 39 μ s).
‧ Programmable CT Ratio (1 to 250).
Model 21(50A) and 23(100A)
‧ W, KW, H.P.
‧ VA, KVA, VAR, KVAR.
‧ PF, Phase Angle ( Φ ).
‧Energy (mWH, WH, KWH).
‧ Analysis of Standby Power Consumption.
‧Balanced 3 Φ Power Quality.
‧Balanced 3 Φ Sequence.
- US$ 396
- Log in for sale price
Power & Harmonics Tester
PROVA-6605
‧Active (W, KW, HP), reactive (VAR, KVAR) and apparent (VA, KVA) power.
‧Power factor (PF), phase angle (Φ), and energy (WH, KWH).
‧Non-interrupted AC current harmonic analysis.
‧1 to 99th order of harmonics at 2.0% basic accuracy.
‧Total harmonic distortion (%THD-F) and crest factor (CF).
‧True RMS measurement of V and A at 0.5% basic accuracy.
‧Fast peak function (39μs for 50 Hz, 33μs for 60Hz).
‧Resistance and Continuity with Beeper
‧Measurement of balanced 3Φ power.
‧Measurement of balanced 3Φ sequence.
‧Programmable CT ratio from 1 to 250.
‧Max, Min and data hold functions.
‧Active power in H.P.
‧Auto power off function in 30 minutes.
‧AC current:0~1500A.
‧Power factor (PF), phase angle (Φ), and energy (WH, KWH).
‧Non-interrupted AC current harmonic analysis.
‧1 to 99th order of harmonics at 2.0% basic accuracy.
‧Total harmonic distortion (%THD-F) and crest factor (CF).
‧True RMS measurement of V and A at 0.5% basic accuracy.
‧Fast peak function (39μs for 50 Hz, 33μs for 60Hz).
‧Resistance and Continuity with Beeper
‧Measurement of balanced 3Φ power.
‧Measurement of balanced 3Φ sequence.
‧Programmable CT ratio from 1 to 250.
‧Max, Min and data hold functions.
‧Active power in H.P.
‧Auto power off function in 30 minutes.
‧AC current:0~1500A.
- US$ 594
- Log in for sale price
Power Harmonics and Leakage Tester
PROVA 19
MODEL PROVA 19, 21, 23
‧ True RMS value (V and A).
‧ Leakage Current Measurement at 10 μ A Resolution.
‧ Harmonic Analysis (V and A) to the 99 th Order.
‧ Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz).
‧ Non-interrupted Harmonic Analysis.
‧ Analysis of Total Harmonic Distortion (THD-F).
‧ Analysis of Crest Factor (C.F.).
‧Fast Peak Function (33 μ s and 39 μ s).
‧ Programmable CT Ratio (1 to 250).
Model 21(50A) and 23(100A)
‧ W, KW, H.P.
‧ VA, KVA, VAR, KVAR.
‧ PF, Phase Angle ( Φ ).
‧Energy (mWH, WH, KWH).
‧ Analysis of Standby Power Consumption.
‧Balanced 3 Φ Power Quality.
‧Balanced 3 Φ Sequence.
‧ True RMS value (V and A).
‧ Leakage Current Measurement at 10 μ A Resolution.
‧ Harmonic Analysis (V and A) to the 99 th Order.
‧ Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz).
‧ Non-interrupted Harmonic Analysis.
‧ Analysis of Total Harmonic Distortion (THD-F).
‧ Analysis of Crest Factor (C.F.).
‧Fast Peak Function (33 μ s and 39 μ s).
‧ Programmable CT Ratio (1 to 250).
Model 21(50A) and 23(100A)
‧ W, KW, H.P.
‧ VA, KVA, VAR, KVAR.
‧ PF, Phase Angle ( Φ ).
‧Energy (mWH, WH, KWH).
‧ Analysis of Standby Power Consumption.
‧Balanced 3 Φ Power Quality.
‧Balanced 3 Φ Sequence.
- US$ 363
- Log in for sale price
Graphic Power Quality Analyzer
PROVA-6200
‧Analysis for Single Phase and Balanced 3 phase system.
‧True RMS Value (V and I).
‧Active Power (K,KW,MW,GW).
‧Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR).
‧Power Factor (PF), Phase Angle( Φ ).
‧Energy (WH,KWH,KVARH,PFH).
‧Programmable PT(1 to 3000)Ratios.
‧Display of Overlapped Voltage and Current Waveform.
‧Maximum Demand (MD in W,KW,MW) with programmable Period.
‧Harmonic Analysis (V and I) to 50th Order.
‧Display of 25 Harmonics in one screen.
‧Optical Isolated RS-232C Interface.
‧Smart Datalogging to save Battery.
‧Datalogging of 32,64,128 or 256 points/cycles.
‧Analysis of Total Harmonic Distortion (%THD-F).
‧Graphic Phasor Diagram.
‧Capture 128 Transient Events (Time+Cycles+Faults) with Programmable Threshold(%),also can be reviewed in LCD.
‧50000 Records with Programmable Interval (1 to 6000 seconds).
‧Real-time Output of Waveform, Power Parameters and Harmonics at Command.
‧Large Dot Matrix LCD Display with Backlight.
‧Power for Long-term Monitoring.
‧Built -in Calendar Clock for Data Logging.
‧True RMS Value (V and I).
‧Active Power (K,KW,MW,GW).
‧Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR).
‧Power Factor (PF), Phase Angle( Φ ).
‧Energy (WH,KWH,KVARH,PFH).
‧Programmable PT(1 to 3000)Ratios.
‧Display of Overlapped Voltage and Current Waveform.
‧Maximum Demand (MD in W,KW,MW) with programmable Period.
‧Harmonic Analysis (V and I) to 50th Order.
‧Display of 25 Harmonics in one screen.
‧Optical Isolated RS-232C Interface.
‧Smart Datalogging to save Battery.
‧Datalogging of 32,64,128 or 256 points/cycles.
‧Analysis of Total Harmonic Distortion (%THD-F).
‧Graphic Phasor Diagram.
‧Capture 128 Transient Events (Time+Cycles+Faults) with Programmable Threshold(%),also can be reviewed in LCD.
‧50000 Records with Programmable Interval (1 to 6000 seconds).
‧Real-time Output of Waveform, Power Parameters and Harmonics at Command.
‧Large Dot Matrix LCD Display with Backlight.
‧Power for Long-term Monitoring.
‧Built -in Calendar Clock for Data Logging.
- US$ 980
- Log in for sale price
Power and Harmonics Analyzer - Model 6801(100A)
PROVA 6830A-1
•Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W.
•True RMS value (V123 and I123).
•Active Power (W, KW, MW, GW).
•Apparent and Reactive Power (KVA, KVAR).
•Power Factor (PF), Phase Angle (Φ).
•Energy (WH, KWH, KVARH, PFH).
•AC Current (see below) and Voltage measurement: True RMS, Auto Range.
1. 6830A+6801: 0.04A to 100A
2. 6830A+6802: 0.4A to 1000A
3. 6830A+3007: 10A to 3000A
4. 6830A+3009: 6A to 1200A
5. 6830A+3006: 20A to 6000A
•Capable of analyzing IT standby power consumption to the maximum demand of a factory.
•Display of 35 Parameters in One Screen (3P4W).
•Programmable CT (1 to 600) and PT (1 to 3000) Ratios.
•Display of Overlapped Voltage and Current Waveform.
•Average Demand (AD in W, KW, MW).
•Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period.
•Harmonic Analysis to the 99th Order.
•Display of 50 Harmonics in one Screen with Waveform.
•Display of Waveform with Peak Values (1024 Samples / Period).
•Analysis of Total Harmonic Distortion (THD-F).
•Graphic Phasor Diagram with 3 Phase System Parameters.
•Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%).
•DIP, SWELL, and OUTAGE are included in transient events.
•3 Phase Voltage or Current Unbalance Ratio (VUR, IUR).
•3 Phase Voltage or Current Unbalance Factor (d0%, d2%).
•Calculated Unbalanced Current through Neutral Line (In).
•512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system).
•Output of Waveform, Power Parameters and Harmonics at Command.
•Large Dot Matrix LCD Display with Backlight.
•Software to work with PC via Optical Isolated RS-232C to USB Interface.
•Built-in timer and calendar for data logging.
Conductor Size:
■ Model 6801(100A) 30mm(approx)
210mm(L)*62mm(W)*36mm(H),200g(Weight)
■ Model 6802(1000A) 55mm(approx),64*24mm(bus bar)
244mm(L)*97mm(W)*46mm(H),600g(Weight)
■ Model 3007 (3000A) 24in/610mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),410g(Weight)
■ Model 3009 (1200A) 18in/460mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),390g(Weight)
■ Model 3006(6000A)
130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
•True RMS value (V123 and I123).
•Active Power (W, KW, MW, GW).
•Apparent and Reactive Power (KVA, KVAR).
•Power Factor (PF), Phase Angle (Φ).
•Energy (WH, KWH, KVARH, PFH).
•AC Current (see below) and Voltage measurement: True RMS, Auto Range.
1. 6830A+6801: 0.04A to 100A
2. 6830A+6802: 0.4A to 1000A
3. 6830A+3007: 10A to 3000A
4. 6830A+3009: 6A to 1200A
5. 6830A+3006: 20A to 6000A
•Capable of analyzing IT standby power consumption to the maximum demand of a factory.
•Display of 35 Parameters in One Screen (3P4W).
•Programmable CT (1 to 600) and PT (1 to 3000) Ratios.
•Display of Overlapped Voltage and Current Waveform.
•Average Demand (AD in W, KW, MW).
•Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period.
•Harmonic Analysis to the 99th Order.
•Display of 50 Harmonics in one Screen with Waveform.
•Display of Waveform with Peak Values (1024 Samples / Period).
•Analysis of Total Harmonic Distortion (THD-F).
•Graphic Phasor Diagram with 3 Phase System Parameters.
•Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%).
•DIP, SWELL, and OUTAGE are included in transient events.
•3 Phase Voltage or Current Unbalance Ratio (VUR, IUR).
•3 Phase Voltage or Current Unbalance Factor (d0%, d2%).
•Calculated Unbalanced Current through Neutral Line (In).
•512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system).
•Output of Waveform, Power Parameters and Harmonics at Command.
•Large Dot Matrix LCD Display with Backlight.
•Software to work with PC via Optical Isolated RS-232C to USB Interface.
•Built-in timer and calendar for data logging.
Conductor Size:
■ Model 6801(100A) 30mm(approx)
210mm(L)*62mm(W)*36mm(H),200g(Weight)
■ Model 6802(1000A) 55mm(approx),64*24mm(bus bar)
244mm(L)*97mm(W)*46mm(H),600g(Weight)
■ Model 3007 (3000A) 24in/610mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),410g(Weight)
■ Model 3009 (1200A) 18in/460mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),390g(Weight)
■ Model 3006(6000A)
130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
- US$ 2475
- Log in for sale price
Flexible Power Quality Tester
AFLEX-3003
‧Flexible probe , different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm.
Power Analysis (3005)
‧W, KW, H.P.
‧VA ,KVA, VAR, KVAR.
‧PF, Phase Angle( Φ ).
‧Energy (WH, KWH).
‧Dual displays (W+PF, VA+KVAR).
‧Balanced 3 Φ Power Quality and Sequence.
Harmonics Analysis
‧True RMS (V and A).
‧3000 A.
‧Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude.
‧Analysis of % THD-F and C.F.
‧Fast Peak Function (33μs and 39μs).
‧Programmable PT (1 to 250 )ratios.
‧Auto - Power - Off : 30 Minutes.
Power Analysis (3005)
‧W, KW, H.P.
‧VA ,KVA, VAR, KVAR.
‧PF, Phase Angle( Φ ).
‧Energy (WH, KWH).
‧Dual displays (W+PF, VA+KVAR).
‧Balanced 3 Φ Power Quality and Sequence.
Harmonics Analysis
‧True RMS (V and A).
‧3000 A.
‧Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude.
‧Analysis of % THD-F and C.F.
‧Fast Peak Function (33μs and 39μs).
‧Programmable PT (1 to 250 )ratios.
‧Auto - Power - Off : 30 Minutes.
- US$ 396
- Log in for sale price
Flexible AC Current Clamp
AFLEX-3001
‧Flexible probe, different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm.
‧True RMS.
‧3000A.
‧Voltage Measurement (AFLEX 3002 only).
‧Fast Peak Function(30 μs).
‧MAX/MIN.
‧Auto-Power-Off:30 minutes.
‧True RMS.
‧3000A.
‧Voltage Measurement (AFLEX 3002 only).
‧Fast Peak Function(30 μs).
‧MAX/MIN.
‧Auto-Power-Off:30 minutes.
- US$ 280
- Log in for sale price