PROVA 200A: 60V, 6A (180W capability)
PROVA 210: 60V, 12A (500W capability)
PROVA 218: 85V, 8.5A (500W capability)
Electrical Specifications: (PROVA 200A)
(23℃±5℃, four-wire measurement, the max. power limit is 180W)
DC Voltage Measurement:
Range |
Resolution |
Accuracy of Reading |
0 ~ 6 V |
0.001 V |
±1% ± (1% of Vopen ± 9mV) |
6 ~ 10 V |
0.001 V |
±1% ± (1% of Vopen ± 0.09V)
|
10 ~ 60 V |
0.01 V |
Vopen: open circuit voltage of solar cell or module.
DC Current Measurement:
Range |
Resolution |
Accuracy of Reading |
0.01 ~ 0.6 A |
0.1 mA |
±1% ± (1% of Ishort ± 0.9mA) |
0.6 ~ 1 A |
0.1 mA |
±1% ± (1% of Ishort ± 9mA) |
1 ~ 6 A |
1 mA |
Ishort: short circuit current of solar cell or module.
Internal Resistance at Ishort: 0.05 Ohm.
DC Current Simulation*
Range |
Resolution |
Accuracy of Reading |
0.01 ~ 1 A |
0.1 mA |
±1% ± 0.9mA |
1 ~ 6 A |
1 mA |
±1% ± 9mA |
* If current is greater than 6A, test (Auto-Scan, Scan, or Test) can not be performed.
* Max. duration of simulation is 9.999 seconds if power is less than 100W.
* Duration of simulation is 10m seconds if power is greater than 100W.
Electrical Specifications: (PROVA 210/218)
(23℃±5℃, 4-wire measurement, max. power limit 500W)
DC Voltage Measurement:
Range |
Resolution |
Accuracy |
0 ~ 10 V |
0.001 V |
±1% ± (1% of Vopen ± 0.1V)
|
10 ~ 60 V (PROVA 210) 10 ~ 85 V (PROVA 218) |
0.01 V |
Vopen: open circuit voltage of solar cell or module.
DC Current Measurement:
Range |
Resolution |
Accuracy |
0.01 ~ 10 A (PROVA 210) 0.01 ~ 8.5 A (PROVA 218) |
1 mA |
±1% ± (1% of Ishort ± 9mA) |
10 ~ 12 A (PROVA 210) |
10 mA |
±1% ± (1% of Ishort ± 0.09A) |
Ishort: short circuit current of solar cell or module.
DC Current Simulation
Range |
Resolution |
Accuracy |
0.01 ~ 10 A (PROVA 210) 0.01 ~ 8.5A (PROVA 218) |
1 mA |
±1% ± 9mA |
10 ~ 12 A (PROVA 210) |
10 mA |
±1% ± 0.09A |
General Specifications:
AC Power Adaptor: |
AC 100V~240V input DC 15V / 1~3A output |
Data Logging Memory Size: |
100 records |
Dimension: |
257(L) x 155(W) x 57(H) mm 10.1" (L) x 6.1" (W) x 2.2" (H) |
Weight: |
1160g / 40.9oz (Batteries included) |
Operation Environment: |
5℃ ~ 50℃, 85% RH |
Storage Environment: |
-20℃ ~ 60℃, 75% RH |
Temperature Coefficient: |
0.1% of full scale / ℃ (<18℃ or >28℃) |
Accessories: |
User manual x 1; Rechargeable lithium battery (PROVA 200A: 1600mAh; PROVA 210/218: 3400mAh) x 1; AC power adaptor x 1; Optical USB cable x 1; Software CD x 1; Software manual x 1; Carrying bag x 1; 4-Wire to 2-Wire connector x 1 set; Kelvin clips (2 clips) x 1 set (PROVA 200A: 6A max; PROVA 210/218: 12A max) |