TES-3660

Autoranging Insulation Tester

Availability: In stock
  • Large LCD with analog bar graph and digital display.
  • 250V, 500V, 1000V output voltage for insulation MΩ testing.
  • insulation testing with automatically switch to
    voltage measurement.
  • LoΩand MΩ function for testing connections.
  • Autodischarge of capacitive voltage charges.
  • Last reading HOLD display. (In MΩ and LoΩ function)
  • AC/DC voltage measurement up to 1000V.
  • Manual data memory and read function (9 sets).
  • Meets EN61557 and IEC61010-1, CAT III 1000V.
  • Size : 235 (L) x 116 (W) x 54(H) mm , (9.3”L x 4.6”W x 2.1”H).
    • Shipping
    • Payments
    • Quantity
    • US$ 248Log in for sale price
    To show price, please join membership and log in.
    Autoranging Insulation Tester
    Autoranging Insulation Tester
    Autoranging Insulation Tester
    Autoranging Insulation Tester
    Autoranging Insulation Tester
    Autoranging Insulation Tester
    Autoranging Insulation Tester
    Autoranging Insulation Tester
    Autoranging Insulation Tester
    Autoranging Insulation Tester
    • Specification
    • Application

     

    q      Insulation Resistance

     

    Range

    Resolution

    Accuracy

    Test Voltages

    4MΩ/40MΩ/400MΩ/4000MΩ/10GΩ

    250V

    4MΩ: 1 KΩ

    40MΩ: 10 KΩ

    400MΩ:100 KΩ

    4000MΩ: 1MΩ

    10GΩ: 10MΩ

    3%+5
    (<1000M)

     

    5%+5
    (>1000M)

    250V+30% ~ -0%

    4MΩ/40MΩ/400MΩ/4000MΩ/10GΩ

    500V

    500V+30% ~ -0%

    4MΩ/40MΩ/400MΩ/4000MΩ/10GΩ

    1000V

    1000V+30% ~ -0%

    Analog Bar Graph

    0 to 10GΩ

    Nominal Current

    1mA

    Circuit Protection

    Test inhibited if input 30V AC or DC

     

    q      LoΩ

     

    Display Range

    40.00Ω

    Measurement Range

    0.01Ω to 40.00Ω

    Accuracy

    2%+2

    Resolution

    0.01Ω

    Analog Bar Graph

    40.00Ω

    Open Circuit Voltage

    6V typical

    Short Circuit Current

    200mA minimum, (0.2 to 2.0Ω)

    Circuit Protection

    Test inhibited if input 30V AC or DC.

     

    q      AC Voltage (40Hz500Hz)                                                                                          Sensitivity : 2V

     

    Range

    Resolution

    Accuracy

    Input Impedance

    Overload Protection

    999V

    1V

    2%+2

    9MΩ

    1000Vrms

     

    q       DC Voltage                                                                                                                    Sensitivity : 2V

     

    Range

    Resolution

    Accuracy

    Input Impedance

    Overload Protection

    999V

    1V

    1%+2

    9MΩ

    1000Vrms

     

    q      Resistance & Continuity (100Ω ± 80Ω)

     

    Range

    Resolution

    Accuracy

    Max. open Circuit Voltage

    Overload Protection

    999.9Ω

    0.1Ω

    1%+3

    3V

    1000Vrms

     

     

     

    Related Products