ELECTRICAL SPECIFICATIONS :
q TRUE power & Apparent power measurement
Input |
Resolution |
Accuracy |
Frequency range |
Overload protection |
V |
0.01 |
±(2%+5) |
45Hz~ |
600V/1100A |
V>130V , A<150A |
||||
V150A |
||||
V>130V , A>150A |
0.1 |
±(2%+1) |
q DCA
Range |
Resolution |
Accuracy |
Overload protection |
5 ~ 1000A |
0.1A |
±( 1.5%rdg+5dgts) |
1100A |
q ACA
Range |
Resolution |
Accuracy |
Frequency range |
Overload protection |
5 ~ 1000A |
0.1A |
±( 1.5%rdg+5dgts) |
45Hz~500Hz |
1100A |
※ Crest Factor :
q DCV
Range |
Resolution |
Accuracy |
Input Impedance |
Overload protection |
5 ~ 600V |
0.1V |
±(0.5%rdg+5dgts) |
1MΩ |
600V |
q ACV
Range |
Resolution |
Accuracy |
Input Impedance |
Frequency Range |
Overload protection |
5 ~ 600V |
0.1V |
± ( 0.5%rdg + 5dgts) |
1MΩ |
45Hz~500Hz |
600Vrms |
※Crest Factor : 3 for stated accuracy
q Peak Indication:
Range |
Resolution |
Accuracy |
Overload protection |
20A~80A |
0.1A |
±(10%rdg+10dgts) |
1100A |
80A~1000A |
±(6%rdg+10dgts) |
※Peak Detect Acquisitions Time ≦1ms
q Peak Indication:
Range |
Resolution |
Accuracy |
Overload protection |
20V~80V |
0.1V |
±(10%rdg+10dgts) |
600Vrms |
80V~600V |
±( 6%rdg+10dgts) |
※Peak Detect Acquisitions Time ≦1ms
q Audible continuity
Range |
Continuity beeper |
Open circuit voltage |
Overload protection |
≦ 0.050 |
≦3.2V |
600Vrms |
q Resistance ( Ω )
Range |
Resolution |
Accuracy |
Open circuit voltage |
Overload protection |
10KΩ |
1Ω |
±( 1 ﹪rdg + 5dgts) |
≦ 3.2 V |
600Vrms |
q Diode test
Range |
Resolution |
Overload protection |
0.001V |
600Vrms |
q Frequency ( Hz )
Range |
Resolution |
Accuracy |
Voltage sensitivity |
Overload protection |
1KHz |
0.1Hz |
±(0.5﹪rdg+5dgts) |
10V or 10A |
600V / 1100A |
5KHz |
1Hz |
q Optional Accessories:
TES-3064 Connecting adaptor & PC software.
General Specifications :
Maximum Voltage between any terminal and earth ground: :600Vrms
Numerical Dual Display :4 digit liquid crystal display (LCD) maximum reading 9999.
Bargraph display :40 Segments.
Battery Life :30hr approx. (Alkaline)
Jaw Opening Diameter :Cables φ46mm.
Operating Temperature :0℃to 50℃ (32℉ to 122℉)
and Humidity R.H. < 80% non-condensing.
Storage Temperature :-10℃to 60℃ (14℉to 140℉)
and Humidity R.H. < 70% non-condensing.
Dimensions :260mm(L) x 93mm(W) x 45mm(H)
Weight :Approx. 450 g
Accessories :Carrying Case, Test leads,
Battery & Instruction manual