TES-3600N

3P4W POWER ANALYZER

Availability: In stock
  • 10 Display Easy - to - View LCD Screen.
  • Connectors for 4 Current Sensing Clamps.
  • 1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement.
  • True RMS Sensing.
  • Power KW, KVAR, KVA, PF,θ,Hz, & Energy KWh, KVARh & KVAh Measurement.
  • Phase sequency indicator function.
  • Backlight display function.
  • Manual Data Memory and Read (99 sets).
  • Data Logging (504KB Memory, 20,000 sets).
  • Programmable Trigger - Points and Start / Stop Time.
  • USB Optical Interface with three phase voltage / current Waveform display and Harmonic analysis.
  • Easy - to - use Push - Button Operation.
  • Light Weight, Portable Design.
    • Shipping
    • Payments
    • Quantity
    • US$ 1499Log in for sale price
    To show price, please join membership and log in.
    3P4W POWER ANALYZER
    3P4W POWER ANALYZER
    • Specification
    • Application

     

    ELECTRICAL SPECIFICATIONS (23±5) :

    q Voltage Measurement (V) :

    Range

    Resolution

    Accuracy

    Input impedance

    Overload protection

    Nominal power system frequency

    999.9V

    0.1V

    ±(0.3%rdg±10dgts) (>10V)

    2MΩ

    1000Vrms

    45Hz ~ 66Hz

    q AC Current Trms Measurement (A) Autoranging :

    Range

    Resolution

    Accuracy

    (including current probe)

    Current probe output

    Overload protection

    Nominal power system frequency

    999.9A

    0.1A

    ±(0.5%rdg±15dgts)
    (>10A)

    0.35mV/A

    1000Arms

    45Hz ~ 66Hz

    q Active Power measurement P (KW) :

    Range

    Resolution

    Accuracy

    999.9KW

    0.1KW

    ±1.0%rdg±20dgts

    q Apparent Power measurement S (KVA) :

    Range

    Resolution

    Accuracy

    999.9KVA

    0.1KVA

    ±1.0%rdg±20dgts

    q Reactive Power measurement Q (KVAR) :

    Range

    Resolution

    Accuracy

    999.9KVAR

    0.1KVAR

    ±1.0%rdg±20dgts

    q Power Factor measurement (COSψ) :

    Range

    Resolution

    Calculated Accuracy

    -1  ~  +1

    0.001

    ±10dgts

    q Phase angle measurement (ψ) :

    Range

    Resolution

    Calculated Accuracy

    +180°~ 0°~ -180°

    0.1°

    ±15dgts

     

    q Frequency measurement (Hz) :

    Range

    Resolution

    Accuracy

    Measurement source

    60HZ

    0.1Hz

    ±0.1%rdg±2dgts

    Voltage U1 > 10V

    q Three Phase Sequency Detection :

    Input voltage range

    Normal phase indication

    Reverse phase indication

    Measurement source

    3P > 10V

    U1, U2 and U3

    q Power Energy measurement (Wh, VAh, varh) :

    Range

    Resolution

    Active power

    accuracy

    Timer interval

    Timer Accuracy

    9.999K

    0.001K

    Wh : ±1.0%rdg±20dgts

     

    VAh : ±1.0%rdg±20dgts

     

    varh : ±1.0%rdg±20dgts

    1 sec

    ±50ppm
    (25
    , 77)

    99.99K

    0.01K

    999.9K

    0.1K

    9.999M

    0.001M

    30.59M

    0.01M

    q Harmonic measurement (use only PC on line analyzer) :

    Order

    Accuracy

    Harmonic Source

    1 ~ 63

    ±3%THD

    U1, U2, U3 > 10V 

    I1, I2, I3 > 10A

    q Waveform (use only PC on line displayed).

    Select Phase A, B or C.

    Select the Voltage and current waveform outputs.

     

     

    General Specifications :

    Size

    235(L)x116(W)x54(H)mm  (9.3"Lx4.6"Wx2.1"H)

    Operating Temperature and  Humidity

    0to 50 (32 to 122) R.H. < 80% non-condensing

    Storage Temperature and  Humidity

    -10to 60 (14to 140) R.H. < 70% non-condensing

    Accessories

     Instruction manual                 ‚Software CD-ROM / Optical USB interface

    ƒDeluxe carrying case         „ Battery ( “AA” 1.5V x 8pcs )

    AC adaptor (110Và12V ; 220Và12V) 

    † 4pcs current clamp transducer (1, 2, 3, 4 cable length 3 meters)
     
     (1000A AC,  jaw opening 42mm)

    ‡ 4pcs crocodiles test leads (blue, yellow, red, black, wire length 3 meters)

     

     