TES-2700

LCR Multimeter

Availability: In stock
  • Autoranging and Auto-power-off.
  • 3200 count LCD with analog bar-graph.
  • Data-hold mode available at ohms.
  • Overload protection up to 600 Vrms.
    • Shipping
    • Payments
    • Quantity
    • US$ 60Log in for sale price
    To show price, please join membership and log in.
    LCR Multimeter
    LCR Multimeter
    • Specification
    • Application

    Electrical Specifications :

    Accuracies aqre ± (…% of reading + …digits) at 23± 5 and below 80% RH.

    DC Voltage : ( Autoranging & Manual range )

    Range

    Resolution

    Accuracy

    Input Impedance

    Overload Protection

    320mV

    0.1mV

    0.5%+2

    > 100MΩ

    AC/DC 750V

    3.2V

    1mV

    11MΩ

    32V

    10mV

    10MΩ

    320V

    100mV

    600V

    1V

    0.8%+2

    AC Voltage : 40Hz400Hz ( Autorange & Manual range )

    Range

    Resolution

    Accuracy

    Input Impedance

    Overload Protection

    3.2V

    100uV

    1.2%+4

    11MΩ

    AC/DC 750V

    32V

    1mV

    10MΩ

    320V

    10mV

    600V

    1V

    DC Current : (uA mA Autoranging & Manual Range) 

    Range

    Resolution

    Accuracy

    Burden Voltage

    Overload Protection

    320uA

    0.1uA

    1%+2

    0.2V max

    0.5A/250V fast blow fuse & Diode

    3200uA

    1uA

    1.8V max

    32mA

    10uA

    1.2V max

    320mA

    100uA

    1.8V max

    20A

    10mA

    1.5%+2

    0.6V max

    20A/380V fast blow fuse
    10A Continuity
    20A for 30 sec. max.

     AC Current : 40Hz400Hz ( uA mA Autorange & Manual range )

    Range

    Resolution

    Accuracy

    Burden Voltage

    Overload Protection

    320uA

    0.1uA

    1.5%+5

    0.2V max

    0.5A/250V fast blow fuse & Diode

    3200uA

    1uA

    1.8V max

    32mA

    10uA

    1.2V max

    320mA

    100uA

    1.8V max

    20A

    10mA

    2.0%+5

    0.6V max

    20A/380V fast blow fuse
    10A Continuity
    20A for 30 sec. max.

    Resistance: ( Autoranging & Manual range )

    Range

    Resolution

    Accuracy

    Open Circuit Voltage

    Overhead protection

    320Ω

    0.1Ω

    0.8%+ 2

    1.3V

    660Vrms

    3.2KΩ

    1Ω

    32KΩ

    10Ω

    320KΩ

    100Ω

    3.2MΩ

    1KΩ

    30MΩ

    10KΩ

    1.5%+ 3


    Diode Test: (  )

    Range

    Resolution

    Short Circuit Current

    Accuracy

    Open Circuit Voltage

    Overload Protection

    1mV

    0.8mA typical

    1%+ 2

    3V

    660Vrms

    Audible Continuity:

    Range

    Resolution

    Max Open Circuit Voltage

    Overload Protection

    20Ω

    1.3V

    660Vrms


    General Specifications:

    1.   Display: 3-1/2 digit liquid crystal display (LCD)
    maximum reading 3200 and Bargraph indication.

    2.   Palarity: Automatic “ -” negative polarity indication.

    3.    Overrange:  “OL” appears on the display.

    4.   Sampling Rate: 12.5 times/sec of Bar-graph indication,

          2 times /sec of digital display

    5.   Power: 2 pcs of  “AAA”  1.5V Battery

    6.   Operating Storage Temperature and Humidity :
    0 to 40, below 80% RH,
    -10 to 60
    , below70% RH.

    7.   Dimensions : 180(L) x 82(W) x 38(H)mm

    8.   Weight : 365g.

    9.   Accessories: Test leads (pair), Spare fuse (0.5A/250V),
    Battery, Operating Instruction.
     
     

     

     

     

     

     

    Related Products