AFLEX-3005

Flexible Power Quality Tester

Availability: In stock
  • AC current measurement up to 3000A (True RMS): basic accuracy 1% of range.
  • AC voltage measurement up to 600V (True RMS): basic accuracy 0.5% of range.
  • AC watt measurement up to 9999KW: basic accuracy 1% of range.
  • Power quality analysis for single and balanced 3 phase system.
  • Measurement of balanced 3Φ power quality and phase sequence.
  • Active (W, KW, HP), Reactive (VAR, KVAR) and Apparent (VA, KVA) power.
  • Power factor (PF), Phase angle (Φ), and Energy (WH, KWH).
  • 1 to 50th order of harmonics at 2.0% basic accuracy.
  • Total harmonic distortion (%THD-F) and Crest factor (CF).
  • Frequency of ACV or ACA: 45 ~ 65 Hz.
  • Fast peak function (39μs for 50 Hz, 33μs for 60Hz).
  • Work with PC via USB interface.
  • Programmable CT ratio from 1 to 250.
  • Max / Min / Data Hold functions.
  • Auto power off function in 30 minutes.
  • Data logging memory size: 8000 records.
    • Shipping
    • Payments
    • Quantity
    • US$ 530Log in for sale price
    To show price, please join membership and log in.
    Flexible Power Quality Tester
    Flexible Power Quality Tester
    • Specification
    • Application

     

    Electrical Specifications: (23±5)

    AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1, V>AC 5V, Current>AC 5A for A range)

    Range (5 to 3000A)

    Resolution

    Accuracy of Readings

    > 20 V and > 30A

    < 20V or < 30A

    10.0 – 999.9 W

    0.1W

    ±1% of range

    ±2% of range

    1.000 – 9.999 KW

    0.001 KW

    ±1% of range

    ±2% of range

    10.00 – 99.99 KW

    0.01 KW

    ±1% of range

    ±2% of range

    100.0 – 999.9 KW

    0.1 KW

    ±1% of range

    ±2% of range

    1000 – 9999 KW

    1 KW

    ±1% of range

    ±2% of range

     

    AC Apparent Power (VA, from 0.000VA to 9999 KVA)

    Range (5 to 3000A)

    Resolution

    Accuracy of Readings

    > 20 V and > 30A

    < 20V or < 30A

    10.0 – 999.9 VA

    0.1VA

    ±1% of range

    ±2% of range

    1.000 – 9.999 KVA

    0.001 KVA

    ±1% of range

    ±2% of range

    10.00 – 99.99 KVA

    0.01 KVA

    ±1% of range

    ±2% of range

    100.0 – 999.9 KVA

    0.1 KVA

    ±1% of range

    ±2% of range

    1000 – 9999 KVA

    1 KVA

    ±1% of range

    ±2% of range

     

    AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR)

    Range (5 to 3000A)

    Resolution

    Accuracy of Readings

    > 20 V and > 30A

    < 20V or < 30A

    10.0 – 999.9 VAR

    0.1VAR

    ±1% of range

    ±2% of range

    1.000 – 9.999 KVAR

    0.001 KVAR

    ±1% of range

    ±2% of range

    10.00 – 99.99 KVAR

    0.01 KVAR

    ±1% of range

    ±2% of range

    100.0 – 999.9 KVAR

    0.1 KVAR

    ±1% of range

    ±2% of range

    1000 – 9999 KVAR

    1 KVAR

    ±1% of range

    ±2% of range

     

    Power Factor (PF)

    Range

    Resolution

    Accuracy

    > 20V and > 30A

    < 20V or < 30A

    0.000 – 1.000

    0.001

    ± 0.04

    ±0.1

     

    AC Current (50 or 60 Hz, Auto Range, True RMS, Crest Factor<4, CT=1)

    Range

    Resolution

    Accuracy of Readings

    5.0 – 300.0A

    0.1A

    ±1% of range

    300.0 – 999.9A

    0.1A

    ±1% of range

    1000 – 3000 A

    1 A

    ±1% of range

     

    AC Voltage (50/60 Hz, Auto Range, TRMS, C.F.<4, Overload Protection AC 800V)

    Range

    Resolution

    Accuracy of Readings

    4.0 V – 600.0 V

    0.1 V

    ±0.5% ± 5dgts

     

    Harmonics of AC Voltage in Percentage

    Range

    Resolution

    Accuracy

    1 – 20th

    0.1%

    ±2%

    21 – 50th

    0.1%

    4% of reading ± 20dgts

     

    Harmonics of AC Voltage in Magnitude

    Range

    Resolution

    Accuracy

    1 – 20th

    0.1V

    ±2% ± 0.5V

    21 – 50th

    0.1V

    4% of reading ±0.5V

     

    Harmonics of AC Current in Percentage

    Range

    Resolution

    Accuracy

    1 – 20th

    0.1%

    ±2%

    21 – 50th

    0.1%

    4% of reading ± 20dgts

     

    Harmonics of AC Current in Magnitude (True RMS300A)

    Range (5 – 300A)

    Resolution

    Accuracy

    1 – 20th

    0.1A

    ±2% of reading ±0.4A

    21 – 50th

    0.1A

    ±4% of reading ±0.4A

     

    Harmonics of AC Current in Magnitude (3000ATrue RMS300A)

    Range

    Resolution

    Accuracy

    1 – 20th

    0.1A

    ±2% of reading ±40A

    21 – 50th

    0.1A

    ±4% of reading ±40A

     

    Phase Angle (Φ, V > 20V, A > 30A)

    Range

    Resolution

    Accuracy

    -180° to 180°

    0.1°

    ± 1°

    0° to 360°

    0.1°

    ± 1°

     

    Total Harmonic Distortion

    Range

    Resolution

    Accuracy

    0.0 – 20%

    0.1%

    ± 2%

    20 – 100%

    0.1%

    ± 6% of reading ± 1%

    100 – 999.9 %

    0.1%

    ± 10% of reading ± 1%

     

    Peak Value of AC Voltage (RMS value > 10V) or AC Current (RMS value > 30A)

    Range

    Sampling Time

    Accuracy of Reading

    50 Hz

    39 μs

    ± 5% ± 30 digits

    60 Hz

    33 μs

    ± 5% ± 30 digits

     

    Crest Factor (C.F.) of ACV (RMS value > 10V) or ACA (RMS value > 30A)

    Range

    Resolution

    Accuracy of Readings

    1.00 – 99.99

    0.01

    ± 5% ± 30 digits

     

     

    Frequency of ACV (RMS value > 10V) or ACA (RMS value > 30A)

    Range

    Resolution

    Accuracy

    45 – 65

    0.1

    ± 0.2Hz

      

     

    General Specifications:

    Probe Length: 3005-24  

    24 in / 610 mm

    Minimum Bending Diameter: 

    35mm

    Connector Diameter:

    23mm

    Cable Diameter:

    14mm

    Cable Length from Probe to Box:

    1700mm

    Cable Length from Box to Output:

    1700mm

    Dimension (Box):

    130mm(L) x 80mm(W)x 43mm(H)

    5.1”(L) x 3.1”(W) x 1.7”(H)

    Battery Type:

    two 1.5V SUM-3

    Battery life:

    200hrs @ 2000mAH.

    Display:

    4+4 digits LCD

    Range Selection:

    Auto

    Overload Indication:       

    OL

    Power Consumption:     

    10mA(approx.)

    Low battery Indication:

    Auto-Power-Off:

    30 minutes after power-on

    LCD Update Time:

    2 times/sec.

    No. Of Samples per Period

    512 (voltage or current)

    256 (power)

    Data logging memory size:

    8000 records

    Data logging sampling time:

    0~600 sec

    Data logging period:      

    8000 x sampling time (0~600 sec.)

    Operating Temperature: 

    5C to 50C

    Operating Humidity:

    15% to 85% RH

    Altitude:

    up to 2000M

    Storage Temperature:

    -20C to 60C

    Storage Humidity:

    15% to 85% RH

    Weight:

    430g (battery included)

    Accessories:

    Test leads

    Carrying case x 1

    Users manual x 1

    Batteries 1.5V x 2

    Software CD x 1

    Software manual x 1

     

     

    Related Products