Flexible Power Quality Tester
- Specification
- Application
Electrical Specifications: (23℃±5℃)
AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1, V>AC 5V, Current>AC 5A for A range)
Range (5 to 3000A) |
Resolution |
Accuracy of Readings |
|
> 20 V and > 30A |
< 20V or < 30A |
||
10.0 – 999.9 W |
0.1W |
±1% of range |
±2% of range |
1.000 – 9.999 KW |
0.001 KW |
±1% of range |
±2% of range |
10.00 – 99.99 KW |
0.01 KW |
±1% of range |
±2% of range |
100.0 – 999.9 KW |
0.1 KW |
±1% of range |
±2% of range |
1000 – 9999 KW |
1 KW |
±1% of range |
±2% of range |
AC Apparent Power (VA, from 0.000VA to 9999 KVA)
Range (5 to 3000A) |
Resolution |
Accuracy of Readings |
|
> 20 V and > 30A |
< 20V or < 30A |
||
10.0 – 999.9 VA |
0.1VA |
±1% of range |
±2% of range |
1.000 – 9.999 KVA |
0.001 KVA |
±1% of range |
±2% of range |
10.00 – 99.99 KVA |
0.01 KVA |
±1% of range |
±2% of range |
100.0 – 999.9 KVA |
0.1 KVA |
±1% of range |
±2% of range |
1000 – 9999 KVA |
1 KVA |
±1% of range |
±2% of range |
AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR)
Range (5 to 3000A) |
Resolution |
Accuracy of Readings |
|
> 20 V and > 30A |
< 20V or < 30A |
||
10.0 – 999.9 VAR |
0.1VAR |
±1% of range |
±2% of range |
1.000 – 9.999 KVAR |
0.001 KVAR |
±1% of range |
±2% of range |
10.00 – 99.99 KVAR |
0.01 KVAR |
±1% of range |
±2% of range |
100.0 – 999.9 KVAR |
0.1 KVAR |
±1% of range |
±2% of range |
1000 – 9999 KVAR |
1 KVAR |
±1% of range |
±2% of range |
Power Factor (PF)
Range |
Resolution |
Accuracy |
|
> 20V and > 30A |
< 20V or < 30A |
||
0.000 – 1.000 |
0.001 |
± 0.04 |
±0.1 |
AC Current (50 or 60 Hz, Auto Range, True RMS, Crest Factor<4, CT=1)
Range |
Resolution |
Accuracy of Readings |
5.0 – 300.0A |
0.1A |
±1% of range |
300.0 – 999.9A |
0.1A |
±1% of range |
1000 – 3000 A |
1 A |
±1% of range |
AC Voltage (50/60 Hz, Auto Range, TRMS, C.F.<4, Overload Protection AC 800V)
Range |
Resolution |
Accuracy of Readings |
4.0 V – 600.0 V |
0.1 V |
±0.5% ± 5dgts |
Harmonics of AC Voltage in Percentage
Range |
Resolution |
Accuracy |
1 – 20th |
0.1% |
±2% |
21 – 50th |
0.1% |
4% of reading ± 20dgts |
Harmonics of AC Voltage in Magnitude
Range |
Resolution |
Accuracy |
1 – 20th |
0.1V |
±2% ± 0.5V |
21 – 50th |
0.1V |
4% of reading ±0.5V |
Harmonics of AC Current in Percentage
Range |
Resolution |
Accuracy |
1 – 20th |
0.1% |
±2% |
21 – 50th |
0.1% |
4% of reading ± 20dgts |
Harmonics of AC Current in Magnitude (True RMS<300A)
Range (5 – 300A) |
Resolution |
Accuracy |
1 – 20th |
0.1A |
±2% of reading ±0.4A |
21 – 50th |
0.1A |
±4% of reading ±0.4A |
Harmonics of AC Current in Magnitude (3000A>True RMS>300A)
Range |
Resolution |
Accuracy |
1 – 20th |
0.1A |
±2% of reading ±40A |
21 – 50th |
0.1A |
±4% of reading ±40A |
Phase Angle (Φ, V > 20V, A > 30A)
Range |
Resolution |
Accuracy |
-180° to 180° |
0.1° |
± 1° |
0° to 360° |
0.1° |
± 1° |
Total Harmonic Distortion
Range |
Resolution |
Accuracy |
0.0 – 20% |
0.1% |
± 2% |
20 – 100% |
0.1% |
± 6% of reading ± 1% |
100 – 999.9 % |
0.1% |
± 10% of reading ± 1% |
Peak Value of AC Voltage (RMS value > 10V) or AC Current (RMS value > 30A)
Range |
Sampling Time |
Accuracy of Reading |
50 Hz |
39 μs |
± 5% ± 30 digits |
60 Hz |
33 μs |
± 5% ± 30 digits |
Crest Factor (C.F.) of ACV (RMS value > 10V) or ACA (RMS value > 30A)
Range |
Resolution |
Accuracy of Readings |
1.00 – 99.99 |
0.01 |
± 5% ± 30 digits |
Frequency of ACV (RMS value > 10V) or ACA (RMS value > 30A)
Range |
Resolution |
Accuracy |
45 – 65 |
0.1 |
± 0.2Hz |
General Specifications:
Probe Length: 3005-24 |
24 in / 610 mm |
Minimum Bending Diameter: |
35mm |
Connector Diameter: |
23mm |
Cable Diameter: |
14mm |
Cable Length from Probe to Box: |
1700mm |
Cable Length from Box to Output: |
1700mm |
Dimension (Box): |
130mm(L) x 80mm(W)x 43mm(H) 5.1”(L) x 3.1”(W) x 1.7”(H) |
Battery Type: |
two 1.5V SUM-3 |
Battery life: |
200hrs @ 2000mAH. |
Display: |
4+4 digits LCD |
Range Selection: |
Auto |
Overload Indication: |
OL |
Power Consumption: |
10mA(approx.) |
Low battery Indication: |
|
Auto-Power-Off: |
30 minutes after power-on |
LCD Update Time: |
2 times/sec. |
No. Of Samples per Period |
512 (voltage or current) 256 (power) |
Data logging memory size: |
8000 records |
Data logging sampling time: |
0~600 sec |
Data logging period: |
8000 x sampling time (0~600 sec.) |
Operating Temperature: |
5C to 50C |
Operating Humidity: |
15% to 85% RH |
Altitude: |
up to 2000M |
Storage Temperature: |
-20C to 60C |
Storage Humidity: |
15% to 85% RH |
Weight: |
430g (battery included) |
Accessories: |