PROVA-23
Power Harmonics and Leakage Tester
Availability: In stock
MODEL PROVA 19, 21, 23 True RMS value (V and A) Leakage Current Measurement at 10 μ A Resolution Harmonic Analysis (V and A) to the 99 th Order Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz) Non-interrupted Harmonic Analysis Analysis of Total Harmonic Distortion (THD-F) Analysis of Crest Factor (C.F.) Fast Peak Function (33 μ s and 39 μ s) Programmable CT Ratio (1 to 250)
Model 21(50A) and 23(100A) W, KW, H.P. VA, KVA, VAR, KVAR PF, Phase Angle ( Φ ) Energy (mWH, WH, KWH) Analysis of Standby Power Consumption Balanced 3 Φ Power Quality Balanced 3 Φ Sequence
- Specification
- Application
Please refer to users manual for more detailed and up-to-date description of specification.
|
|
AC Watt (50 or 60 Hz, PF 0.5 to 1. CT = 1, Accuracy of Readings)
Model 21 (0 to 50A), Model 23 (0 to 100A)
|
Range
|
Resolution
|
Accuracy 21 (0 - 30A)
Accuracy 23 (0 - 60A)
|
Accuracy 21 (30 - 50A)
Accuracy 23 (60 - 100A)
|
0.000 – 9.999 W
|
0.001 W
|
±1% ± 0.02 W
|
±2% of VA ± 5dgts
|
10.00 – 99.99 W
|
0.01 W
|
±1% ± 0.2 W
|
±2% of VA ± 5dgts
|
100.0 – 999.9 W
|
0.1 W
|
±1% ± 0.2 W
|
±2% of VA ± 5dgts
|
1.000 – 9.999 KW
|
0.001 KW
|
±1% ± 0.02 KW
|
±2% of VA ± 5dgts
|
10.00 – 99.99 KW
|
0.01 KW
|
±1% ± 0.2 KW
|
±2% of VA ± 5dgts
|
100.0 – 999.9 KW
|
0.1 KW
|
±1% ± 0.2 KW
|
±2% of VA ± 5dgts
|
1000 – 9999 KW
|
1 KW
|
±1% ± 2 KW
|
±2% of VA ± 5dgts
|
|
AC Current (50 or 60 Hz, True RMS) |
Range (Model 19,21)
|
Range (Model 23)
|
Resolution
|
Accuracy of Readings
|
0.30 – 60.00mA
|
0.30 – 60.00mA
|
0.01mA
|
±0.5% ± 5dgts
|
60.0 – 600.0mA
|
60.0 – 600.0mA
|
0.1mA
|
±0.5% ± 5dgts
|
0.030 – 3.000 A
|
0.030 – 9.999 A
|
0.001 A
|
±0.5% ± 5dgts
|
3.00 – 30.00 A
|
10.00 – 60.00 A
|
0.01 A
|
±0.5% ± 5dgts
|
30.00 – 50.00 A
|
6 0.00 – 99.99 A
|
0.01 A
|
±1.0% ± 5dgts
|
|
AC Voltage (50 or 60 Hz, True RMS) |
Range
|
Resolution
|
Accuracy of R.
|
Range
|
Resolution
|
Accuracy of R.
|
3V – 250V
|
0.1 V
|
±0.5% ± 5dgts
|
250V – 600V
|
0.1 V
|
±0.5% ± 5dgts
|
|
Harmonics of AC Voltage in % and Magnitude (1 to 99th order) |
Range
|
Resolution
|
Accuracy in %
|
Resolution
|
Accuracy in Magnitude
|
50V – 600V
|
0.1 %
|
±0.5%
|
0.1 V
|
±0.5% ± 0.5V
|
|
Harmonics of ACA in % Percentage and Magnitude (1 to 99th order) |
Range (Model 19, 21)
|
Range (Model 23)
|
Res.
|
Accuracy (%)
|
Res.
|
Accuracy of R.
|
10.00 – 60.00mA
|
10.00 – 60.00mA
|
0.1 %
|
±0.5%
|
0.01mA
|
±0.5% ± 0.1mA
|
60.0 – 600.0mA
|
60.0 – 600.0mA
|
0.1 %
|
±0.5%
|
0.1mA
|
±0.5% ± 1mA
|
0.5 – 3.000 A
|
0.5 – 9.999 A
|
0.1 %
|
±0.5%
|
0.001 A
|
±0.5% ± 0.01 A
|
3.00 – 30.00 A
|
10.00 – 60.00 A
|
0.1 %
|
±0.5%
|
0.01 A
|
±0.5% ± 0.1 A
|
30.00 – 60.00 A
|
6 0.00 – 99.99 A
|
0.1 %
|
±1.0%
|
0.01 A
|
±1.0% ± 0.1 A
|
|
Power Factor and Phase Angle (PF, Φ ,Model 21 and 23) |
Range (PF)
|
Resolution
|
Accuracy
|
Range (Φ)
|
Resolution
|
Accuracy
|
0.000 – 1.000
|
0.001
|
± 1°
|
-180° to 180° (0 ° to 360 ° )
|
0.1°
|
± 1°
|
|
Total Harmonic Distortion (THD-F, 1 to 99th order) Crest Factor (C.F., Accuracy of Readings) |
Range
|
Resolution
|
Accuracy of R.
|
Range
|
Resolution
|
Accuracy of R.
|
0.0–999.9%
|
0.1%
|
± 0.5% ± 5 digits
|
1.00 – 99.99
|
0.01
|
± 5% ± 30 digits
|
|
Conductor Size |
30mm (approx.) |
Battery Type |
1.5V SUM-3 x 2 |
Display |
4+2+2 digits LCD |
Power Consumption |
5mA (approx.) |
Auto-Power-Off |
30 minutes |
No. Of Samples/Period |
512 (V & A), 256 (W) |
LCD update rate |
2 times / sec. |
Weight |
200g (battery included) |
Operating Temperature |
-10 ° C to 50° C |
Operating Humidity |
< 85% relative |
Storage Temperature |
-20° C to 60° C |
Storage Humidity |
< 75% relative |
Dimension |
210 (L) x 62 (W) x 35.6mm (H), 8.3" (L) x 2.5" (W) x 1.4" (H) |
Accessories |
test leads, Carrying bag x 1, Users manual x 1, Batteries 1.5V x 2 |
Option |
alligator clips |
|
Related Products
-
PROVA 6830A-5
Power and Harmonics Analyzer - Model 3006 (6000A)
【This is the pre-order product; it will be taken 5-7 days to ship after making an order.】
•Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W
•True RMS value (V123 and I123)
•Active Power (W, KW, MW, GW)
•Apparent and Reactive Power (KVA, KVAR)
•Power Factor (PF), Phase Angle (Φ)
•Energy (WH, KWH, KVARH, PFH)
•AC Current (see below) and Voltage measurement: True RMS, Auto Range.
1. 6830A+6801: 0.04A to 100A
2. 6830A+6802: 0.4A to 1000A
3. 6830A+3007: 10A to 3000A
4. 6830A+3009: 6A to 1200A
5. 6830A+3006: 20A to 6000A
•Capable of analyzing IT standby power consumption to the maximum demand of a factory
•Display of 35 Parameters in One Screen (3P4W)
•Programmable CT (1 to 600) and PT (1 to 3000) Ratios
•Display of Overlapped Voltage and Current Waveform
•Average Demand (AD in W, KW, MW)
•Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period
•Harmonic Analysis to the 99th Order
•Display of 50 Harmonics in one Screen with Waveform
•Display of Waveform with Peak Values (1024 Samples / Period)
•Analysis of Total Harmonic Distortion (THD-F)
•Graphic Phasor Diagram with 3 Phase System Parameters
•Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
•DIP, SWELL, and OUTAGE are included in transient events.
•3 Phase Voltage or Current Unbalance Ratio (VUR, IUR)
•3 Phase Voltage or Current Unbalance Factor (d0%, d2%)
•Calculated Unbalanced Current through Neutral Line (In)
•512K Memory with Programmable Interval
(Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system)
•Output of Waveform, Power Parameters and Harmonics at Command
•Large Dot Matrix LCD Display with Backlight
•Software to work with PC via Optical Isolated RS-232C to USB Interface
•Built-in timer and calendar for data logging
Conductor Size:
■ Model 6801(100A) 30mm(approx)
210mm(L)*62mm(W)*36mm(H),200g(Weight)
■ Model 6802(1000A) 55mm(approx),64*24mm(bus bar)
244mm(L)*97mm(W)*46mm(H),600g(Weight)
■ Model 3007 (3000A) 24in/610mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),410g(Weight)
■ Model 3009 (1200A) 18in/460mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),390g(Weight)
■ Model 3006(6000A)
130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
- US$ 2475
- Log in for sale price
-
PROVA 6830A-4
Power and Harmonics Analyzer - Model 3009 (1200A)
【This is the pre-order product; it will be taken 5-7 days to ship after making an order.】
•Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W
•True RMS value (V123 and I123)
•Active Power (W, KW, MW, GW)
•Apparent and Reactive Power (KVA, KVAR)
•Power Factor (PF), Phase Angle (Φ)
•Energy (WH, KWH, KVARH, PFH)
•AC Current (see below) and Voltage measurement: True RMS, Auto Range.
1. 6830A+6801: 0.04A to 100A
2. 6830A+6802: 0.4A to 1000A
3. 6830A+3007: 10A to 3000A
4. 6830A+3009: 6A to 1200A
5. 6830A+3006: 20A to 6000A
•Capable of analyzing IT standby power consumption to the maximum demand of a factory
•Display of 35 Parameters in One Screen (3P4W)
•Programmable CT (1 to 600) and PT (1 to 3000) Ratios
•Display of Overlapped Voltage and Current Waveform
•Average Demand (AD in W, KW, MW)
•Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period
•Harmonic Analysis to the 99th Order
•Display of 50 Harmonics in one Screen with Waveform
•Display of Waveform with Peak Values (1024 Samples / Period)
•Analysis of Total Harmonic Distortion (THD-F)
•Graphic Phasor Diagram with 3 Phase System Parameters
•Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
•DIP, SWELL, and OUTAGE are included in transient events.
•3 Phase Voltage or Current Unbalance Ratio (VUR, IUR)
•3 Phase Voltage or Current Unbalance Factor (d0%, d2%)
•Calculated Unbalanced Current through Neutral Line (In)
•512K Memory with Programmable Interval
(Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system)
•Output of Waveform, Power Parameters and Harmonics at Command
•Large Dot Matrix LCD Display with Backlight
•Software to work with PC via Optical Isolated RS-232C to USB Interface
•Built-in timer and calendar for data logging
Conductor Size:
■ Model 6801(100A) 30mm(approx)
210mm(L)*62mm(W)*36mm(H),200g(Weight)
■ Model 6802(1000A) 55mm(approx),64*24mm(bus bar)
244mm(L)*97mm(W)*46mm(H),600g(Weight)
■ Model 3007 (3000A) 24in/610mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),410g(Weight)
■ Model 3009 (1200A) 18in/460mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),390g(Weight)
■ Model 3006(6000A)
130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
- US$ 2475
- Log in for sale price
-
PROVA 6830A-3
Power and Harmonics Analyzer - Model 3007 (3000A)
【This is the pre-order product; it will be taken 5-7 days to ship after making an order.】
•Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W
•True RMS value (V123 and I123)
•Active Power (W, KW, MW, GW)
•Apparent and Reactive Power (KVA, KVAR)
•Power Factor (PF), Phase Angle (Φ)
•Energy (WH, KWH, KVARH, PFH)
•AC Current (see below) and Voltage measurement: True RMS, Auto Range.
1. 6830A+6801: 0.04A to 100A
2. 6830A+6802: 0.4A to 1000A
3. 6830A+3007: 10A to 3000A
4. 6830A+3009: 6A to 1200A
5. 6830A+3006: 20A to 6000A
•Capable of analyzing IT standby power consumption to the maximum demand of a factory
•Display of 35 Parameters in One Screen (3P4W)
•Programmable CT (1 to 600) and PT (1 to 3000) Ratios
•Display of Overlapped Voltage and Current Waveform
•Average Demand (AD in W, KW, MW)
•Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period
•Harmonic Analysis to the 99th Order
•Display of 50 Harmonics in one Screen with Waveform
•Display of Waveform with Peak Values (1024 Samples / Period)
•Analysis of Total Harmonic Distortion (THD-F)
•Graphic Phasor Diagram with 3 Phase System Parameters
•Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
•DIP, SWELL, and OUTAGE are included in transient events.
•3 Phase Voltage or Current Unbalance Ratio (VUR, IUR)
•3 Phase Voltage or Current Unbalance Factor (d0%, d2%)
•Calculated Unbalanced Current through Neutral Line (In)
•512K Memory with Programmable Interval
(Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system)
•Output of Waveform, Power Parameters and Harmonics at Command
•Large Dot Matrix LCD Display with Backlight
•Software to work with PC via Optical Isolated RS-232C to USB Interface
•Built-in timer and calendar for data logging
Conductor Size:
■ Model 6801(100A) 30mm(approx)
210mm(L)*62mm(W)*36mm(H),200g(Weight)
■ Model 6802(1000A) 55mm(approx),64*24mm(bus bar)
244mm(L)*97mm(W)*46mm(H),600g(Weight)
■ Model 3007 (3000A) 24in/610mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),410g(Weight)
■ Model 3009 (1200A) 18in/460mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),390g(Weight)
■ Model 3006(6000A)
130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
- US$ 2475
- Log in for sale price
-
PROVA 6830A-2
Power and Harmonics Analyzer - Model 6802(1000A)
【This is the pre-order product; it will be taken 5-7 days to ship after making an order.】
•Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W
•True RMS value (V123 and I123)
•Active Power (W, KW, MW, GW)
•Apparent and Reactive Power (KVA, KVAR)
•Power Factor (PF), Phase Angle (Φ)
•Energy (WH, KWH, KVARH, PFH)
•AC Current (see below) and Voltage measurement: True RMS, Auto Range.
1. 6830A+6801: 0.04A to 100A
2. 6830A+6802: 0.4A to 1000A
3. 6830A+3007: 10A to 3000A
4. 6830A+3009: 6A to 1200A
5. 6830A+3006: 20A to 6000A
•Capable of analyzing IT standby power consumption to the maximum demand of a factory
•Display of 35 Parameters in One Screen (3P4W)
•Programmable CT (1 to 600) and PT (1 to 3000) Ratios
•Display of Overlapped Voltage and Current Waveform
•Average Demand (AD in W, KW, MW)
•Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period
•Harmonic Analysis to the 99th Order
•Display of 50 Harmonics in one Screen with Waveform
•Display of Waveform with Peak Values (1024 Samples / Period)
•Analysis of Total Harmonic Distortion (THD-F)
•Graphic Phasor Diagram with 3 Phase System Parameters
•Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
•DIP, SWELL, and OUTAGE are included in transient events.
•3 Phase Voltage or Current Unbalance Ratio (VUR, IUR)
•3 Phase Voltage or Current Unbalance Factor (d0%, d2%)
•Calculated Unbalanced Current through Neutral Line (In)
•512K Memory with Programmable Interval
(Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system)
•Output of Waveform, Power Parameters and Harmonics at Command
•Large Dot Matrix LCD Display with Backlight
•Software to work with PC via Optical Isolated RS-232C to USB Interface
•Built-in timer and calendar for data logging
Conductor Size:
■ Model 6801(100A) 30mm(approx)
210mm(L)*62mm(W)*36mm(H),200g(Weight)
■ Model 6802(1000A) 55mm(approx),64*24mm(bus bar)
244mm(L)*97mm(W)*46mm(H),600g(Weight)
■ Model 3007 (3000A) 24in/610mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),410g(Weight)
■ Model 3009 (1200A) 18in/460mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),390g(Weight)
■ Model 3006(6000A)
130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
- US$ 2475
- Log in for sale price
-
PROVA-21
Power Harmonics and Leakage Tester
MODEL PROVA 19, 21, 23
‧ True RMS value (V and A)
‧ Leakage Current Measurement at 10 μ A Resolution
‧ Harmonic Analysis (V and A) to the 99 th Order
‧ Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz)
‧ Non-interrupted Harmonic Analysis
‧ Analysis of Total Harmonic Distortion (THD-F)
‧ Analysis of Crest Factor (C.F.)
‧Fast Peak Function (33 μ s and 39 μ s)
‧ Programmable CT Ratio (1 to 250)
Model 21(50A) and 23(100A)
‧ W, KW, H.P.
‧ VA, KVA, VAR, KVAR
‧ PF, Phase Angle ( Φ )
‧Energy (mWH, WH, KWH)
‧ Analysis of Standby Power Consumption
‧Balanced 3 Φ Power Quality
‧Balanced 3 Φ Sequence
- US$ 396
- Log in for sale price
-
-
PROVA 1660
Transformer Turns Ratio Meter
‧Measurements of 1Φand 3ΦTransformer/VT/CT Turns Ratio.
‧VT/PT ratio 0.8~10000, CT ratio 0.8~2000.
‧Graphical and Literal Illustration of Measurements and Connections with Large Back-lighted Dot Matrix 240 x 128 LCD. Display Test Data with Nameplate Transformer Values for Easy Interpretation.
‧Ten Test Frequencies (50~400Hz).
‧Display Turns Ratio, Deviation, Secondary Output, Excitation Voltage and Current, Phase Angle and Nameplate Transformer/VT/CT Values in one page for easy transformer quality interpretation.
‧Check for Live Test Points, Short Circuit, Open Circuit, and Reverse Polarity before Each Measurement. Message is displayed to Warn Users (But, checking is not performed once measurement starts).
‧Store 4096 Files of Transformer Nameplate Values (VT/PT/CT, 1Φ/3Φ, Test Frequency, Primary and Secondary Voltages or Ratio, RCF) and Measuring Data.
‧9 types of 3Φ Windings Connections pre-installed for easy user selection.
‧Wireless Blue Tooth Communication with PC.
‧Select Filter to Remove Field Noise (Slow, Normal, Fast).
‧Disable or Enable Auto-Power-Off with Programmable Time.
‧Built-in calendar clock.
Records with Date and Time Stamp.
‧Powerful Lithium Battery (3400mAH) with built-in Charging Circuit.
‧User Programmable RCF (Reference Correction Factor, 0.99~1.01) to Correct Accuracy within 1% Error.
‧Friendly File System for Easy On-site Data Retrieval and Nameplate Values Management.
‧PC Application Software included.
- US$ 2228
- Log in for sale price
-
PROVA 19
Power Harmonics and Leakage Tester
MODEL PROVA 19, 21, 23
‧ True RMS value (V and A)
‧ Leakage Current Measurement at 10 μ A Resolution
‧ Harmonic Analysis (V and A) to the 99 th Order
‧ Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz)
‧ Non-interrupted Harmonic Analysis
‧ Analysis of Total Harmonic Distortion (THD-F)
‧ Analysis of Crest Factor (C.F.)
‧Fast Peak Function (33 μ s and 39 μ s)
‧ Programmable CT Ratio (1 to 250)
Model 21(50A) and 23(100A)
‧ W, KW, H.P.
‧ VA, KVA, VAR, KVAR
‧ PF, Phase Angle ( Φ )
‧Energy (mWH, WH, KWH)
‧ Analysis of Standby Power Consumption
‧Balanced 3 Φ Power Quality
‧Balanced 3 Φ Sequence
- US$ 363
- Log in for sale price
-
PROVA-6200
Graphic Power Quality Analyzer
‧Analysis for Single Phase and Balanced 3 phase system
‧True RMS Value (V and I)
‧Active Power (K,KW,MW,GW)
‧Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR)
‧Power Factor (PF), Phase Angle( Φ )
‧Energy (WH,KWH,KVARH,PFH)
‧Programmable PT(1 to 3000)Ratios
‧Display of Overlapped Voltage and Current Waveform
‧Maximum Demand (MD in W,KW,MW) with programmable Period
‧Harmonic Analysis (V and I) to 50th Order
‧ Display of 25 Harmonics in one screen
‧Optical Isolated RS-232C Interface
‧Smart Datalogging to save Battery
‧Datalogging of 32,64,128 or 256 points/cycles
‧Analysis of Total Harmonic Distortion (%THD-F)
‧Graphic Phasor Diagram
‧Capture 128 Transient Events (Time+Cycles+Faults) with Programmable Threshold(%),also can be reviewed in LCD
‧50000 Records with Programmable Interval (1 to 6000 seconds)
‧Real-time Output of Waveform, Power Parameters and Harmonics at Command
‧Large Dot Matrix LCD Display with Backlight
‧Power for Long-term Monitoring
‧Built -in Calendar Clock for Data Logging
- US$ 980
- Log in for sale price
-
PROVA 6830A-1
Power and Harmonics Analyzer - Model 6801(100A)
【This is the pre-order product; it will be taken 5-7 days to ship after making an order.】
•Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W
•True RMS value (V123 and I123)
•Active Power (W, KW, MW, GW)
•Apparent and Reactive Power (KVA, KVAR)
•Power Factor (PF), Phase Angle (Φ)
•Energy (WH, KWH, KVARH, PFH)
•AC Current (see below) and Voltage measurement: True RMS, Auto Range.
1. 6830A+6801: 0.04A to 100A
2. 6830A+6802: 0.4A to 1000A
3. 6830A+3007: 10A to 3000A
4. 6830A+3009: 6A to 1200A
5. 6830A+3006: 20A to 6000A
•Capable of analyzing IT standby power consumption to the maximum demand of a factory
•Display of 35 Parameters in One Screen (3P4W)
•Programmable CT (1 to 600) and PT (1 to 3000) Ratios
•Display of Overlapped Voltage and Current Waveform
•Average Demand (AD in W, KW, MW)
•Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period
•Harmonic Analysis to the 99th Order
•Display of 50 Harmonics in one Screen with Waveform
•Display of Waveform with Peak Values (1024 Samples / Period)
•Analysis of Total Harmonic Distortion (THD-F)
•Graphic Phasor Diagram with 3 Phase System Parameters
•Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
•DIP, SWELL, and OUTAGE are included in transient events.
•3 Phase Voltage or Current Unbalance Ratio (VUR, IUR)
•3 Phase Voltage or Current Unbalance Factor (d0%, d2%)
•Calculated Unbalanced Current through Neutral Line (In)
•512K Memory with Programmable Interval
(Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system)
•Output of Waveform, Power Parameters and Harmonics at Command
•Large Dot Matrix LCD Display with Backlight
•Software to work with PC via Optical Isolated RS-232C to USB Interface
•Built-in timer and calendar for data logging
Conductor Size:
■ Model 6801(100A) 30mm(approx)
210mm(L)*62mm(W)*36mm(H),200g(Weight)
■ Model 6802(1000A) 55mm(approx),64*24mm(bus bar)
244mm(L)*97mm(W)*46mm(H),600g(Weight)
■ Model 3007 (3000A) 24in/610mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),410g(Weight)
■ Model 3009 (1200A) 18in/460mm(Probe Length)
130mm(L)*80mm(W)*43mm(H),390g(Weight)
■ Model 3006(6000A)
130mm(L) x 80mm(W) x 43mm(H),430g(Weight)
- US$ 2475
- Log in for sale price
Copyright © 2016 Instaligo Inc. All rights reserved