TES-3050H

TRMS AC/DC Clamp Meter

Availability: In stock
  • 3-3/4 Digital LCD with bar-graph.
  • Auto-Ranging on Volt, Ohm, Current, Frequency measurements.
  • Auto-power off.
  • Data Hold mode.
  • MAX/MIN Hold mode.
  • Zero Adjustment/Relative Reading.
  • PEAK Hold mode.(only ACV and ACA Range)
    • Shipping
    • Payments
    • Quantity
    • US$ 198Log in for sale price
    To show price, please join membership and log in.
    TRMS AC/DC Clamp Meter
    TRMS AC/DC Clamp Meter
    • Specification
    • Application

     

    MEASUREMENT SPECIFICATIONS:

    DC Current (Autorange & Manual)

    Range

    Resolution

    Accuracy

    Overload protection

    400A

    0.1A

    ±(2% + 5)

    1100A

    1000A

    1A

    Response time: 5 seconds max. to rated accuracy within selected range.

    AC Current (Autorange & Manual): Low Pass Filter

    Range

    Resolution

    Accuracy

    Overload protection

    Frequency

    Response

    400A

    0.1A

    ±(2% + 10)

    1100A

    40450 Hz

    1000A

    1A

    Conversion type: AC coupled, TRMS measurement.

    Additional Crest Factor Errors (non - sinecure)

    Crest Factor

    Error (% of reading)

    1 - 3

    0.5%

    3 - 5

    3%

    5 - 7

    6%

    Response time: 5 seconds max, to rated accuracy within selected range.

    INFLUENCE OUANTITY

    Influence quantity

    Limits of variation

    Measured quantity

    Tolerance

    Position of conductor in the clamp conductor’s diameter: 20mm

    In relation to the center

    Amps

    ±(1%+5)

     DC Voltage (Autorange & Manual)

    Range

    Resolution

    Accuracy

    Input Impedance

    Overload protection

    400mV

    0.1mV

    ±(0.75% + 2)

    11MΩ

    600Vrms

    4V

    0.001V

    10MΩ

    40V

    0.01V

    400V

    0.1V

    600V

    1V

     Response time: 3 seconds max. to rated accuracy within selected range.

    AC Voltage (Autorange & Manual): Low Pass Filter 

    Range

    Resolution

    Accuracy

    Input impedance

    Overload protection

    Frequency

    Response

    4V

    0.001V

    ±(1.2%+5)

    11MΩ

    600Vrms

    40450 Hz

    40V

    0.01V

    10MΩ

    400V

    0.1V

    600V

    1V

    ±(1.5%+5)

    Conversion type: AC coupled, TRMS measurement.

    Additional Crest Factor Errors (non - sinecure)

    Crest Factor

    Error (% of reading)

    1 - 3

    0.5%

    3 - 5

    3%

    5 - 7

    6%

    Response time: 5 seconds max, to rated accuracy within selected range.

    Frequency (Hz) (Autorange for Voltage)

    Range

    Resolution

    Accuracy

    Sensitivity

    Overload protection

    100Hz

    0.01Hz

    ±(0.1% + 2)

    100mV

    600Vrms

    1KHz

    0.1Hz

    5KHz

    0.001KHz

    Frequency (Hz) (Autorange for Current)

    Range

    Resolution

    Accuracy

    Sensitivity

    Overload protection

    100Hz

    0.01Hz

    ±(0.5% + 5)

    5A

    1100A

    1KHz

    0.1Hz

     

    Resistance (Ω) (Autorange & Manual)

    Range

    Resolution

    Accuracy

    Open circuit

    Voltage

    Overload protection

    400Ω

    0.1Ω

    ±(1% + 5)

    0.5 VDC

    600Vrms

    4KΩ

    0.001KΩ

    ±(1% + 3)

    40KΩ

    0.01KΩ

    400KΩ

    0.1KΩ

    4MΩ

    0.001MΩ

    40MΩ

    0.01MΩ

    ±(1.5% + 3)

    Audible continuity 

    Range

    Continuity beeper

    Open Circuit Voltage

    Overload  protection

    40Ω

    0.5V

    600Vrms

    Diode test  

    Range

    Resolution

    Accuracy

    Overload protection

    0.001V

    ±(1%+2)

    600Vrms

    Max. open circuit Voltage: 3.2V

    Max. short circuit Current: 1.0mA (typical).

    Peak Hold Specifications 

    AC Voltage (Manual Range): Low Pass Filter

    Range
    Resolution
    Accuracy 
     (50Hz
    60Hz)
    Input Impedance
    Overload protection
    4V
    0.001V
    ±(2.5% + 10)
     11MΩ
    600Vrms
    40V
    0.01V
     10MΩ
    400V
    0.1V
    600V
    1V

     AC Current (Manual Range): Low Pass Filter

    Range

    Resolution

    Accuracy
    (50Hz
    60Hz)

    Overload protection

    400A

    0.1A

    ±(2.5 % + 10)

    1100A

    1000A

    1A

    Peak Detect Acquisitions Time100ms

    Peak Hold: storage of the peak value. 

     

     SPECIFICATIONS:

      Numerical Display3-3/4 digit liquid crystaldisplay (LCD) maximum reading 3999.

      Range Selection All ranges are selected  by a single range switch.

      Over Range Indication  : LCD will show a "OL" flashing in the highest position accompanied with a continuous beeping.

                                                     (except for ranges of 1000A AC/DC, and 600VDC 600VAC ).

      Low Battery Indication  : The  is displayed when the battery voltage drops below the operating voltage.

      Sampling Rate   20 times/sec ( Barograph )  2 times/secDigital Display

      Power Source    one 006p 9V or IEC 6F22  or NEDA 1604 Battery.

      Battery Life         100hr approx. (Alkaline)

      Polarity               Automatic polarity " "  display for negative input.

      Auto power off time  Approx. 30 minutes 

      Operating Temperature  : 0°C to 50°C(32°F to 122°F)  and Humidity below 80%RH   

      Storage Temperature     : -10°C to 60°C(14°F to 140°F) and Humidity below 70%RH                            

      Dimensions  :  239(L)×66(W)×34(H)mm

      Weight  :  Approx. 430g 

      Accessories :  Instruction manual, Battery, Test leads,Carry Case.

     

     

    Related Products